Frontal slab composite magnetic resonance neurography of the brachial plexus: implications for infraclavicular block approaches.
نویسندگان
چکیده
BACKGROUND Magnetic resonance neurography (MRN) is an imaging method by which nerves can be selectively highlighted. Using commercial software, the authors explored a variety of approaches to develop a three-dimensional volume-rendered MRN image of the entire brachial plexus and used it to evaluate the accuracy of infraclavicular block approaches. METHODS With institutional review board approval, MRN of the brachial plexus was performed in 10 volunteer subjects. MRN imaging was performed on a GE 1.5-tesla magnetic resonance scanner (General Electric Healthcare Technologies, Waukesha, WI) using a phased array torso coil. Coronal STIR and T1 oblique sagittal sequences of the brachial plexus were obtained. Multiple software programs were explored for enhanced display and manipulation of the composite magnetic resonance images. The authors developed a frontal slab composite approach that allows single-frame reconstruction of a three-dimensional volume-rendered image of the entire brachial plexus. Automatic segmentation was supplemented by manual segmentation in nearly all cases. For each of three infraclavicular approaches (posteriorly directed needle below midclavicle, infracoracoid, or caudomedial to coracoid), the targeting error was measured as the distance from the MRN plexus midpoint to the approach-targeted site. RESULTS Composite frontal slabs (coronal views), which are single-frame three-dimensional volume renderings from image-enhanced two-dimensional frontal view projections of the underlying coronal slices, were created. The targeting errors (mean +/- SD) for the approaches-midclavicle, infracoracoid, caudomedial to coracoid-were 0.43 +/- 0.67, 0.99 +/- 1.22, and 0.65 +/- 1.14 cm, respectively. CONCLUSION Image-processed three-dimensional volume-rendered MNR scans, which allow visualization of the entire brachial plexus within a single composite image, have educational value in illustrating the complexity and individual variation of the plexus. Suggestions for improved guidance during infraclavicular block procedures are presented.
منابع مشابه
Magnetic resonance imaging demonstrates lack of precision in needle placement by the infraclavicular brachial plexus block described by Raj et al.
UNLABELLED The infraclavicular brachial plexus block first described by Raj et al. was supposed to anesthetize all the main peripheral nerves of the brachial plexus without the risk of pneumothorax. However, in performing the block, we have had difficulties finding the nerves at the cord level. Therefore, we questioned whether the recommended needle direction (the "Raj line") guides the needle ...
متن کاملA novel infraclavicular brachial plexus block: the lateral and sagittal technique, developed by magnetic resonance imaging studies.
UNLABELLED A new infraclavicular brachial plexus block method has the patient supine with an adducted arm. The target is any of the three cords behind the pectoralis minor muscle. The point of needle insertion is the intersection between the clavicle and the coracoid process. The needle is advanced 0 degrees -30 degrees posterior, always strictly in the sagittal plane next to the coracoid proce...
متن کاملUse of magnetic resonance imaging to define the anatomical location closest to all three cords of the infraclavicular brachial plexus.
Infraclavicular techniques are often used to perform brachial plexus blocks. In our volunteer study we used magnetic resonance imaging to identify the brachial plexus and axillary vessels in a sagittal plane corresponding to the lateral sagittal infraclavicular block. In 20 volunteers, all cords were positioned within 2 cm from the artery approximately within 2/3 of a circle. We derived an inje...
متن کاملCase scenario: postoperative brachial plexopathy associated with infraclavicular brachial plexus blockade: localizing postoperative nerve injury.
383 August 2014 P OSTOPERATIVE nerve injuries (PNIs) have anesthetic, patient, and surgical contributions and determining the etiology may be challenging when peripheral nerve blockade is used. Evaluating PNI relies on clinical assessment, electrodiagnostic testing, and magnetic resonance imaging (MRI). MRI of peripheral nerves can diagnose external compression or loss of nerve continuity and i...
متن کاملLow-Volume Brachial Plexus Block Providing Surgical Anesthesia for Distal Arm Surgery Comparing Supraclavicular, Infraclavicular, and Axillary Approach: A Randomized Observer Blind Trial
Background. Distal arm surgery is widely performed under regional anesthesia with brachial plexus block. The preponderance of evidence for the efficacy relies upon injection of local anesthetic in excess of 30 mL. We aimed to compare three different ultrasound-guided brachial plexus block techniques restricting the total volume to 20 mL. Methods. 120 patients were prospectively randomized to ul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 103 6 شماره
صفحات -
تاریخ انتشار 2005