The physical and biological doses of methacholine are different for Mefar MB3 and Jaeger APS sidestream nebulizers.

نویسندگان

  • Georg Praml
  • Eva Scharrer
  • Dorothea de la Motte
  • Dennis Nowak
  • Gerhard Scheuch
  • Knut Sommerer
  • Katja Radon
چکیده

BACKGROUND Within a study on respiratory symptoms in rural areas, we used the European Community Respiratory Health Survey methacholine challenge protocol. For quicker and more reliable handling, we had to change the nebulizer in the bronchial challenge system from Mefar model MB3 (Bovezzo, Italy) to Jaeger APS Sidestream (similar to Mefar; Würzburg, Germany). Therefore, we compared the physical properties of the two systems, adapted the challenge protocol, and compared the results of both systems in subjects with and without airway hyperresponsiveness to methacholine. METHOD The physical properties of both systems were characterized by the residual method indicating a similar particle size distribution and an average output of 6 muL/s for Mefar MB3 and 1.25 muL/s for APS Sidestream. In the comparison study, 34 subjects were included. Airway responsiveness was quantified by provocative dose of methacholine causing a 20% fall in FEV(1). RESULTS A significant difference was found between the two challenge systems (p =0.004, McNemar test). Nine subjects reached a 20% drop in FEV(1) with the APS Sidestream only. The FEV(1) dropped by > 20% using either system in eight subjects. In 17 subjects, none of the two systems caused a 20% decrease in FEV(1). CONCLUSION Even if the physical dose is determined with elaborate methods, the biological dose may vary between two nebulizer systems, causing incomparable outcomes for subjects tested with different systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of aerosol output from the Mefar dosimeter: implications for epidemiological studies.

Standardized methods for the measurement of airway responsiveness may use the Mefar MB3 inhalation dosimeter to generate standard doses of methacholine aerosol. The manufacturer provides calibrated output data for every nebulizer, so that a standard output may be achieved by varying nebulization time. This output is, however, measured by weight loss (WL), which may over-estimate true aerosol ou...

متن کامل

Variation in nebulizer aerosol output and weight output from the Mefar dosimeter: implications for multicentre studies.

The active aerosol component of nebulizers is less than 100% of output by weight, and may vary between nebulizers in different batches from the same manufacturer. A measure of bronchial responsiveness to methacholine, which can overcome this problem, is required. One hundred and sixty nebulizers from 21 centres in the European Community Respiratory Health Survey (ECRHS) were calibrated for aero...

متن کامل

Variation in bronchial responsiveness in the European Community Respiratory Health Survey (ECRHS).

Attempts to compare bronchial responsiveness between populations have been hampered by between-study differences in the pharmacological agent of provocation, the method of administration and the summary statistic employed. The European Community Respiratory Health Survey used methacholine challenge delivered by Mefar dosimeter according to a standardized protocol used in 35 centres in 16 countr...

متن کامل

Asthma: Respiratory Symptoms, Atopy and Bronchial Hyperresponsiveness in Young Adults in Estonia and Sweden

Jõgi, R. 2001. Asthma: Respiratory Symptoms, Atopy and Bronchial Hyperresponsiveness in Young Adults in Estonia and Sweden. Acta Universitatis Upsaliensis. Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine 1076. 64 pp. Uppsala. ISBN 91-554-5119-5. Morbidity of asthma has increased over the world. The reasons for this increase have remained unclear. Studies in childre...

متن کامل

Variation in nebulizer output and weight output from Mefar dosimeter: implications for multicentre studies.

We wish to comment upon the paper of CHINN et al. [1] in which both weight and aerosol output data were given for 193 Mefar nebulizers from 27 centres involved in the European Community Respiratory Health Survey (ECRHS). A single centre in Turin determined nebulizer output using the sodium fluoride (NaF) tracer method described by DENNIS et al. [2]. The weight output was given as 11 mg·s-1 with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 128 5  شماره 

صفحات  -

تاریخ انتشار 2005