Thickness Dependent Effective Viscosity of a Polymer Solution near an Interface Probed by a Quartz Crystal Microbalance with Dissipation Method
نویسندگان
چکیده
The solution viscosity near an interface, which affects the solution behavior and the molecular dynamics in the solution, differs from the bulk. This paper measured the effective viscosity of a dilute poly (ethylene glycol) (PEG) solution adjacent to a Au electrode using the quartz crystal microbalance with dissipation (QCM-D) technique. We evidenced that the effect of an adsorbed PEG layer can be ignored, and calculated the zero shear rate effective viscosity to remove attenuation of high shear frequency oscillations. By increasing the overtone n from 3 to 13, the thickness of the sensed polymer solution decreased from ~70 to 30 nm. The zero shear rate effective viscosity of the polymer solution and longest relaxation time of PEG chains within it decrease with increasing solution thickness. The change trends are independent of the relation between the apparent viscosity and shear frequency and the values of the involved parameter, suggesting that the polymer solution and polymer chains closer to a solid substrate have a greater effective viscosity and slower relaxation mode, respectively. This method can study the effect of an interface presence on behavior and phenomena relating to the effective viscosity of polymer solutions, including the dynamics of discrete polymer chains.
منابع مشابه
Periodic swelling and collapse of polyelectrolyte brushes driven by chemical oscillation.
Poly(acrylic acid) (PAA) chains exhibit conformational change in response to pH, whereas bromate-sulfite-ferrocyanide (BSF) solution shows pH oscillation between 3.2 and 6.6. By use of quartz crystal microbalance with dissipation (QCM-D), we have investigated the pH induced conformational change of PAA brushes under a continuous flow of BSF solution in real time. The changes in frequency and di...
متن کاملQuartz crystal microbalance studies on conformational change of polymer chains at interface.
The conformation of polymers at interface profoundly influences the interfacial properties. Quartz crystal microbalance with dissipation (QCM-D) is a newly developed technique to detect polymer behavior at interface in real time. In this article, we mainly review our QCM-D studies. Our focus is on temperature induced collapse and swelling of tethered polymer chains, pancake-to-brush transition ...
متن کاملHydration and chain entanglement determines the optimum thickness of poly(HEMA-co-PEG₁₀MA) brushes for effective resistance to settlement and adhesion of marine fouling organisms.
Understanding how surface physicochemical properties influence the settlement and adhesion of marine fouling organisms is important for the development of effective and environmentally benign marine antifouling coatings. We demonstrate that the thickness of random poly(HEMA-co-PEG10MA) copolymer brushes affect antifouling behavior. Films of thicknesses ranging from 50 to 1000 Å were prepared vi...
متن کاملVariations in coupled water, viscoelastic properties, and film thickness of a Mefp-1 protein film during adsorption and cross-linking: a quartz crystal microbalance with dissipation monitoring, ellipsometry, and surface plasmon resonance study.
We have measured the time-resolved adsorption kinetics of the mussel adhesive protein (Mefp-1) on a nonpolar, methyl-terminated (thiolated) gold surface, using three independent techniques: quartz crystal microbalance with dissipation monitoring (QCM-D), surface plasmon resonance, and ellipsometry. The QCM-D and ellipsometry data shows that, after adsorption to saturation of Mefp-1, cross-linki...
متن کاملInvestigating the properties of supported vesicular layers on titanium dioxide by quartz crystal microbalance with dissipation measurements.
Adsorption of phospholipid vesicles on titanium dioxide was studied by a combination of quartz crystal microbalance with dissipation (QCM-D) and atomic force microscopy techniques. Vesicle size, concentration in solution, and bilayer composition were systematically varied. A strong dependence of the QCM-D response (magnitude of the frequency and dissipation factor shifts) on the vesicle concent...
متن کامل