Light scattering model for donor lenses as a function of depth
نویسندگان
چکیده
The amount of light scattered by normal donor lenses (n = 15, ages 43-82 years) from a 1 x 0.1 mm white slit beam was measured as a function of depth in the lens for seven angles from 10 to 165 degrees, and for four wavelengths from 400 to 700 nm. Apart from the most superficial layers, the data could be described with a model that consisted of three components. (1) small sized protein particles (alpha-crystallin), (2) large sized protein particles and (3) spectrally neutral rough surface reflectance ('zones of discontinuity'). Component (1) and (3) dominate backward scattering. Component (2) dominates forward scattering, but occupies only around 0.000006 of the lens volume, with the lowest values in the nucleus. Component (3) is important for a small range of backward directions only, being much stronger in extranuclear areas than in the nucleus.
منابع مشابه
Depth-dependent forward light scattering by donor lenses.
PURPOSE To determine quantitatively forward light scattering in the human lens as a function of depth. To use this to explain the psychophysical result, verified earlier in vitro, showing total light scattering in the human lens to decrease with scattering angle according to an approximate power law (power -2). METHODS The amount of light scattered by donor lenses (n = 15; age range, 43 to 82...
متن کاملLight scattering by donor lenses as a function of depth and wavelength.
PURPOSE To determine quantitatively dependence on the wavelength and angle, as a function of depth, of light scattering in the human lens. To compare the result for forward directions with psychophysical data. To derive candidate particle distributions that might be responsible for nuclear light scattering as significant in the psychophysical situation. METHODS The amount of light scattered b...
متن کاملEngineering of core/shell nanoparticles surface plasmon for increasing of light penetration depth in tissue (modeling and analysis)
Objectives: In this article, a new procedure for increasing the light penetration depth in a tissue is studied and simulated. It has been reported that the most important problem in biomedical optical imaging relates to the light penetration depth, and so this makes a dramatic restriction on its applications. In the optical imaging method, the detection of the backscattered pho...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملThe ciliary corona: physical model and simulation of the fine needles radiating from point light sources.
PURPOSE Most people see, around bright lights against dark backgrounds, a radiating pattern of numerous fine, slightly colored needles of light-the so called ciliary corona. The purpose of this study was to try to explain this phenomenon. METHODS Recently, it has been shown that light-scattering in the eye, measured psychophysically and on human donor lenses, can be explained assuming the pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 39 شماره
صفحات -
تاریخ انتشار 1999