Cyclic voltammetric simulation for electrochemically mediated enzyme reaction and determination of enzyme kinetic constants.

نویسندگان

  • K Yokoyama
  • Y Kayanuma
چکیده

A cyclic voltammetric simulation that can be applied to an electrochemically mediated enzyme reaction involving any substrate and mediator concentrations was developed. Concentration polarization of the substrate in the vicinity of an electrode was considered as well as mediator concentration. Reversible and quasi-reversible electrochemical reactions with one electron followed by an enzyme reaction with two electrons were modeled. The differential equations for the mediator and substrate were solved using digital simulation techniques. The calculated cyclic voltammograms showed prepeaks when there was a low substrate concentration, high mediator concentration, and high enzyme activity. Digital simulation was applied to the determination of the kinetic constants of glucose oxidase (GOx). Cyclic voltammetry was carried out experimentally in a phosphate buffer solution containing GOx, ferrocene derivatives, and glucose. The ratio of the catalytic to the diffusion-controlled current, ik/id, was evaluated. The kcat, KMM, and KMS values were determined from the current values obtained by simulation and by experimentation at various enzyme, mediator, and substrate concentrations. The kcat, KMM, and KMS values for GOx, ferrocenedimethanol, and glucose were 340 s-1, 110 microM, and 30 mM, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical Synthesis and Kinetic Evaluation of Electrooxidation of Acetaminophen in the Presence of Antidepressant Drugs

With the aim of obtaining information about drug-drug interaction (DDI) between acetaminophen and some of antidepressant drugs (fluoxetine, sertraline and nortriptyline), in the present work we studied the electrochemical oxidation of acetaminophen (paracetamol) in the presence of these drugs by means of cyclic voltammetry and Controlled-potential coulometry. The reaction between N-acetyl-p-ben...

متن کامل

Electrochemical Synthesis and Kinetic Evaluation of Electrooxidation of Acetaminophen in the Presence of Antidepressant Drugs

With the aim of obtaining information about drug-drug interaction (DDI) between acetaminophen and some of antidepressant drugs (fluoxetine, sertraline and nortriptyline), in the present work we studied the electrochemical oxidation of acetaminophen (paracetamol) in the presence of these drugs by means of cyclic voltammetry and Controlled-potential coulometry. The reaction between N-acetyl-p-ben...

متن کامل

Voltammetric Determination of Curcumin in Spices using Platinum Electrode Electrochemically Modified with Poly(Vanillin-co-Caffeic Acid)

In this study a simple, highly sensitive, and selective electrochemical method was developed for determination of the low concentration curcumin (CUR) using a poly(vanillin-co-caffeic acid) p(Van-CA) modified platinum electrode. Electrode modification was carried out electrochemically with cyclic voltammetry (CV) method. For this purpose; a solution of 6 mM vanillin (Van) and 6 mM caff...

متن کامل

Determination of kinetic parameters for interfacial enzymatic reactions on self-assembled monolayers.

This paper reports a method to characterize the kinetic constants for the action of enzymes on immobilized substrates. This example uses cutinase, a serine esterase that hydrolyzes 4-hydroxyphenyl valerate moieties that are immobilized on a self-assembled monolayer of alkanethiolates on gold. The product of the enzyme reaction is a hydroquinone, which is redox active and therefore permits the u...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 70 16  شماره 

صفحات  -

تاریخ انتشار 1998