Treatment planning comparison of IMPT, VMAT and 4π radiotherapy for prostate cases

نویسندگان

  • Angelia Tran
  • Jingjing Zhang
  • Kaley Woods
  • Victoria Yu
  • Dan Nguyen
  • Gary Gustafson
  • Lane Rosen
  • Ke Sheng
چکیده

BACKGROUND Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. METHODS Ten prostate patients were planned using IMPT with robustness optimization, VMAT, and 4π to an initial dose of 54 Gy to a clinical target volume (CTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2 Gy to the prostate for a total dose of 79.2 Gy. The IMPT plans utilized two coplanar, oblique scanning beams 10° posterior of the lateral beam positions. Range uncertainties were taken into consideration in the IMPT plans. VMAT plans used two full, coplanar arcs to ensure sufficient PTV coverage. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams using a greedy column generation algorithm. CTV doses, bladder and rectum dose volumes (V40, V45, V60, V65, V70, V75, and V80), R100, R50, R10, and CTV homogeneity index (D95/D5) were evaluated. RESULTS Compared to IMPT, 4π resulted in lower anterior rectal wall mean dose as well as lower rectum V40, V45, V60, V65, V70, and V75. Due to the opposing beam arrangement, IMPT resulted in significantly (p < 0.05) greater femoral head doses. However, IMPT plans had significantly lower bladder, rectum, and anterior rectal wall max dose. IMPT doses were also significantly more homogeneous than 4π and VMAT doses. CONCLUSION Compared to the VMAT and 4π plans, IMPT treatment plans are superior in CTV homogeneity and maximum point organ-at-risk (OAR) doses with the exception of femur heads. IMPT is inferior in rectum and bladder volumes receiving intermediate to high doses, particularly to the 4π plans, but significantly reduced low dose spillage and integral dose, which are correlated to secondary cancer for patients with expected long survival. The dosimetric benefits of 4π plans over VMAT are consistent with the previous publication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.&nbsp; Material...

متن کامل

A treatment planning comparison of volumetric modulated arc therapy and proton therapy for a sample of breast cancer patients treated with post-mastectomy radiotherapy.

Post-mastectomy radiotherapy (PMRT) has been shown to improve disease-free survival and overall survival for locally advanced breast cancer. However, long term survivors may develop life threatening acute and chronic treatment-related toxicities after radiotherapy, like cardiac toxicity and second cancers. The more advanced techniques like volumetric arc therapy (VMAT), and proton therapy have ...

متن کامل

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

Feasibility of prostate robotic radiation therapy on conventional C-arm linacs.

PURPOSE Significant dosimetric improvement for radiation therapy using optimized noncoplanar fields has been previously demonstrated. The purpose here is to study the feasibility of optimized robotic noncoplanar radiation therapy, termed 4π therapy, for prostate cancer treatments on a conventional C-arm linac. METHODS AND MATERIALS Twelve low-risk prostate cancer patients previously treated b...

متن کامل

Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases

The aim of this work was to compare different approaches to VMAT optimization (biological vs. physical DVH-based) in two commercial treatment planning systems (TPS) for head and neck and prostate cases, using Pareto fronts. VMAT vs. IMRT Pareto front comparison was additionally performed in order to benchmark the optimizer efficiency and VMAT plan quality for each TPS. Three prostate and three ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017