Soft Pressure Sensing Sleeve for Direct Cardiac Compression Device

نویسنده

  • Markus A. Horvath
چکیده

A direct cardiac compression (DCC) device is a non-blood contacting sleeve placed around the failing heart to actively assist blood pumping function. For design optimization of a DCC device, it is necessary to monitor the surface pressure exerted on the heart surface at multiple points during active assist, and to correlate this with device performance and cardiac output. In this paper, we present the design, fabrication and characterization of a soft, elastic, conformable pressure sensing sleeve that is placed at the heart/device interface to monitor device performance without affecting device function. This sleeve enables identification of optimal pre-tensioning, positioning and user-controlled parameters of the DCC device. Individual sensors (8x8x3 mm) were fabricated using a surface mount device (SMD) barometer on a custom double-sided flexible printed circuit board and casting the assembly in urethane rubber. A typical sensor has a dynamic range of 2.5 kPa to 50 kPa with a sensitivity of 11.3 counts per kPa. An array of up to 24 sensors was integrated into a flexible, stretchable circuit embedded in a thin (500 micron) silicone sheet using a multi-step layering fabrication process. Continuous magnet wires were wrapped around an alignment fixture, soldered to individual sensors in place and the entire circuit was transfer printed on to a silicone sheet. This assembly allows stretch corresponding to the fractional shortening of the heart muscles (up to 50%). The sleeve successfully measured static and dynamic pressures with a mechanical tensile tester and did not affect DCC device performance. Preliminary results demonstrated that the sleeve is robust enough to withstand >10000 cycles, compression forces from the DCC device and can achieve sensing range and repeatability suitable for procedural pressure monitoring for a DCC device. In addition to allowing performance measurements for iterating DCC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Draft: Design and Fabrication of a Soft Robotic Direct Cardiac Compression Device

A direct cardiac compression (DCC) device is an active sleeve that is surgically placed around the heart to help the failing heart to pump without contacting blood. Soft robotic techniques enable fabrication of a conformable DCC device containing modular actuators oriented in a biomimetic manner that can restore the natural motion of the heart and provide tunable active assistance. In this pape...

متن کامل

Wearable Soft Robotic Device Supports the Failing Heart in vivo

Soft robots fabricated from low modulus, compliant materials hold significant potential for medical device applications that warrant safe, synergistic interaction with humans. We have recently applied this technology to develop ventricular assistive devices (VADs) that can externally massage the failing heart [1][2]. In heart failure (HF), the heart cannot provide sufficient pumping support to ...

متن کامل

The Hydromechanics of Edema Fluid in Lymphedematous Lower Limb During Intermittent Pneumatic Compression.

This article presents results of computer simulations of the hydro-mechanical processes in the lymphedematous tissue under stress of a single chamber of sleeve for pneumatic compression. The discussion was focused on parameters of compression as pressures and inflation times to squeeze out the mobile tissue fluid from the edematous tissue. Simulations have predicted that the process of squeezin...

متن کامل

Physiological and hemodynamic evaluation of nonuniform direct cardiac compression.

BACKGROUND Biventricular direct cardiac compression (DCC) has the potential to support the failing heart without the complications associated with a blood/device interface encountered with the use of current ventricular assist devices. A clinically designed DCC device that provides compression pressure around the base of the heart in synchrony with native ventricular contractions was evaluated ...

متن کامل

Hemodynamic alterations in venous blood flow produced by external pneumatic compression.

Venous stasis associated with prolonged bed rest can enhance the risk of deep venous thrombosis (DVT). Pneumatic compression of the lower extremities can reduce this risk by preventing venous stasis. When selecting a method of leg compression for their patients, physicians must chose between two distinctly different types of compression devices. One device applies pressure with a single-chamber...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015