Performance of Orbitrap mass analyzer at various space charge and non-ideal field conditions: simulation approach.

نویسندگان

  • Andriy Kharchenko
  • Gleb Vladimirov
  • Ron M A Heeren
  • Eugene N Nikolaev
چکیده

The orbital trap mass analyzer provides a number of unique analytical features along with inevitable limitations as an electrostatic instrument operating in high space charge regimes resulting in systematic measured frequency errors as an effect of stored ion clouds on the trap field and each other effect of non-ideal machining the trap electrodes, effect of injection slot, effect of real versus theoretical trap dimensions, etc. This paper deals with determining the influence of the space charge effect and imperfection of the electrostatic field on the motion of ion ensembles in the orbital trap. We examine effects of theoretically modeled non-harmonicity of the electrostatic potential and the number of confined ions on stability of coherent ion motion in the trap that determines the frequency shifts of axial ion oscillation. Three different Orbitrap geometries were considered: geometry close to preproduction Orbitrap, close to standard Orbitrap, close to high field Orbitrap. Frequency shifts for m/z = 500 and for charge state +23 of cytochrome c isotopic cluster particles with 10(4)-6*10(6) elemental charges in the trap were considered. Refined spectra were calculated using the filter diagonalization method proposed by Mandelshtam et al. and applied to mass spectrometry by O'Connor and Aizikov.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Orbitrap: a new mass spectrometer.

Research areas such as proteomics and metabolomics are driving the demand for mass spectrometers that have high performance but modest power requirements, size, and cost. This paper describes such an instrument, the Orbitrap, based on a new type of mass analyzer invented by Makarov. The Orbitrap operates by radially trapping ions about a central spindle electrode. An outer barrel-like electrode...

متن کامل

Orbitrap mass spectrometry: instrumentation, ion motion and applications.

Since its introduction, the orbitrap has proven to be a robust mass analyzer that can routinely deliver high resolving power and mass accuracy. Unlike conventional ion traps such as the Paul and Penning traps, the orbitrap uses only electrostatic fields to confine and to analyze injected ion populations. In addition, its relatively low cost, simple design and high space-charge capacity make it ...

متن کامل

Advances in bioanalytical LC-MS using the Orbitrap™ mass analyzer.

The continuing desire to analyze complex biological samples with the minimum number of steps places high demands on increasing speed, dynamic signal range, quantitative capability and the facility with which the mass spectrometers can interface with chromatographic separation methods. Reliable identification of metabolites in complex mixtures requires robust mass spectrometers with high resolvi...

متن کامل

Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer.

Design and performance of a novel hybrid mass spectrometer is described. It couples a linear ion trap mass spectrometer to an orbitrap mass analyzer via an rf-only trapping quadrupole with a curved axis. The latter injects pulsed ion beams into a rapidly changing electric field in the orbitrap wherein they are trapped at high kinetic energies around an inner electrode. Image current detection i...

متن کامل

Study by simulation the influence of temperature on the formation of space charge in the dielectric multilayer Under DC Electric stress

Multidielectric polyethylene is a material that is generally employed as insulation for  the HVDC isolations. In this paper, the influence of temperature on space charge dynamics has been studied, low-density polyethylene (LDPE) and Fluorinated Ethylene Propylene (FEP) sandwiched between two electrodes were subjected to voltage application of 5kV (14.3 kV/mm) for extended duration of time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2012