Left ventricular markers of global dyssynchrony predict limited exercise capacity in heart failure, but not in patients with preserved ejection fraction

نویسندگان

  • Gani Bajraktari
  • Arlind Batalli
  • Afrim Poniku
  • Artan Ahmeti
  • Rozafa Olloni
  • Violeta Hyseni
  • Zana Vela
  • Besim Morina
  • Rina Tafarshiku
  • Driton Vela
  • Premtim Rashiti
  • Edmond Haliti
  • Michael Y Henein
چکیده

BACKGROUND The aim of this study was to prospectively examine echocardiographic parameters that correlate and predict functional capacity assessed by 6 min walk test (6-MWT) in patients with heart failure (HF), irrespective of ejection fraction (EF). METHODS In 147 HF patients (mean age 61 ± 11 years, 50.3% male), a 6-MWT and an echo-Doppler study were performed in the same day. Global LV dyssynchrony was indirectly assessed by total isovolumic time - t-IVT [in s/min; calculated as: 60 - (total ejection time + total filling time)], and Tei index (t-IVT/ejection time). Patients were divided into two groups based on the 6-MWT distance (Group I: ≤ 300 m and Group II: >300 m), and also in two groups according to EF (Group A: LVEF ≥ 45% and Group B: LVEF < 45%). RESULTS In the cohort of patients as a whole, the 6-MWT correlated with t-IVT (r = -0.49, p < 0.001) and Tei index (r = -0.43, p < 0.001) but not with any of the other clinical or echocardiographic parameters. Group I had lower hemoglobin level (p = 0.02), lower EF (p = 0.003), larger left atrium (p = 0.02), thicker interventricular septum (p = 0.02), lower A wave (p = 0.01) and lateral wall late diastolic myocardial velocity a' (p = 0.047), longer isovolumic relaxation time (r = 0.003) and longer t-IVT (p = 0.03), compared with Group II. In the patients cohort as a whole, only t-IVT ratio [1.257 (1.071-1.476), p = 0.005], LV EF [0.947 (0.903-0.993), p = 0.02], and E/A ratio [0.553 (0.315-0.972), p = 0.04] independently predicted poor 6-MWT performance (<300 m) in multivariate analysis. None of the echocardiographic measurements predicted exercise tolerance in HFpEF. CONCLUSION In patients with HF, the limited exercise capacity, assessed by 6-MWT, is related mostly to severity of global LV dyssynchrony, more than EF or raised filling pressures. The lack of exercise predictors in HFpEF reflects its multifactorial pathophysiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure after percutaneous coronary intervention.Material and Methods: Fifty patients with left ventricular ejection fraction ≤ 40% undergone percutaneous coronary intervention were r...

متن کامل

Acute left ventricular dysfunction secondary to right ventricular septal pacing in a woman with initial preserved contractility: a case report

INTRODUCTION Right ventricular apical pacing-related heart failure is reported in some patients after long-term pacing. The exact mechanism is not yet clear but may be related to left ventricular dyssynchrony induced by right ventricular apical pacing. Right ventricular septal pacing is thought to deteriorate left ventricular function less frequently because of a more normal left ventricular ac...

متن کامل

Gender related predictors of limited exercise capacity in heart failure

Aim The aim of this study was to investigate the impact of gender on the prediction of limited exercise capacity in heart failure (HF) patients assessed by 6 minute walk test (6-MWT). Methods In 147 HF patients (mean age 61 ± 11 years, 50.3% male), a 6-MWT and a Doppler echocardiographic study were performed in the same day. Conventional cardiac measurements were obtained and global LV dyssyn...

متن کامل

Speckle tracking echocardiography-determined measures of global and regional left ventricular function correlate with functional capacity in patients with and without preserved ejection fraction

BACKGROUND Standard measures of left ventricular systolic and diastolic function often fail to identify left ventricular dysfunction in patients with heart failure and do not correlate with measures of functional capacity. AIM To determine if speckle tracking echocardiography (STE)-determined measures of global and regional myocardial contractility have a linear association with functional ca...

متن کامل

Left ventricular dyssynchrony in patients with heart failure and preserved ejection fraction.

AIMS Mechanical dyssynchrony has been postulated to play a pathophysiologic role in heart failure with preserved ejection fraction (HFpEF). METHODS AND RESULTS We quantified left ventricular (LV) systolic dyssynchrony in 130 HFpEF patients with NYHA class II-IV symptoms, ejection fraction (EF) ≥45%, and NT-proBNP levels >400 pg/mL enrolled in the PARAMOUNT trial, and compared them to 40 healt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2012