The influence of ventilation tube design on the magnitude of stress imposed at the implant/tympanic membrane interface.
نویسندگان
چکیده
The design of ventilation tubes or grommets is thought to have a considerable influence on their performance. A computational model (finite element method) was used to investigate the significance of four design parameters of a commonly used design of ventilation tube. The design parameters were: the length of the shaft, the diameter of the flanges, the thickness of the flanges, and the material type. A statistical analysis technique, known as a factorial analysis of variance, was used to examine the importance of the four design parameters on the dynamical behaviour of the middle ear with the implant in situ and on the magnitude of stress induced at the implant/tympanic membrane interface. We predicted that the ventilation tube alters the frequency response of the middle ear; specifically the shaft length and the thickness of the flanges were found to have a significant effect upon the vibratory pattern at the umbo. A reduced length of tube and an increased size of flange were also found to be significant for minimising membrane stress (both with P<0.001). Thus, design parameters of critical influence on optimising performance were identified.
منابع مشابه
A Comparison of Extrusion Time of Ventilating Tube (pariz) with mported v.t (Shepard) in Patients Affected with Chronic Serous Otitis
ABSTRACT Otitis serous is a common disease in pediatrics and ENT which can be treated by various medical and surgical techniques. The traditional surgery treatment of this disease has been done by realation of middle ear cavity with myringotomy and insertion of ventilation tube in tympanic membrane. Since remaining time of ventilation tube in tympanic membrane has a direct effect on the tratm...
متن کاملPREVALENCE OF TRAUMATIC TYMPANIC MEMBRANE PERFORATION IN PATIENTS WITH A PATULOUS EUSTACHIAN TUBE
Background: With respect to physical relations in force and pressure, we hypothesized that the prevalence of traumatic tympanic membrane perforation in patients with a patulous Eustachian tube is greater than normal, because in Eustachian tube patency, the internal air pressure of the middle ear will not increase after compression, subsequent to trauma. Therefore the force upon the tympanic...
متن کاملOtological Findings Ten Years after Myringotomy with Tympanostomy Tube Insertion
Introduction: To study the long-term complications of tympanostomy tube insertion in young children 10 years after surgery. Materials and Methods: In September 2011, the medical records of all patients who had undergone myringotomy with tympanostomy tube insertion between February 2000 and March 2001 at the two general hospitals of Isfahan University of Medical Sciences were studied. Of t...
متن کاملCement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration
Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...
متن کاملIncidence of Complications Developed after the Insertion of Ventilation Tube in Children under 6 years old in 2008-2009
Introduction: One of the main treatments of chronic otitis media with effusion is ventilation of the middle ear with a ventilation tube (VT). The objective of this study was to determine the incidence and the types of VT complications in children with otitis media with effusion in Ahwaz. Materials and Methods: In this prospective study, the medical records of 208 children (52 male and 35 female...