Separation of serum creatine kinase isoenzymes by ion-exchange column chromatography.

نویسندگان

  • B Klein
  • J A Foreman
  • C L Jeunelot
  • J E Sheehan
چکیده

We describe a practical, technically convenient DEAE-Sephadex chromatographic column and a three-fraction salt-gradient elution procedure, with which serum creatine kinase activity is rapidly and quantitatively separated into the isoenzyme components with excellent analytical recovery of the total activity applied. The homogeneity of the isoenzyme fractions was demonstrated by electrophoresis and rechromatography. Sera assessed by the Mercer fractionation [Clin. Chem. 20, 36 (1974)] and the present procedure showed excellent agreement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of tissue and serum creatine kinase isoenzymes by ion-exchange column chromatography.

I describe a simple, rapid anion-exchange column chromatographic technique for separating the creatine kinase (CK) isoenzymes in human serum and tissue. Extracts of CK-rich tissues (skeletal muscle, cardiac muscle, and brain) were used to determine optimum conditions for separating CK isoenzymes MM, MB, and BB. Samples, layered on mini-columns (0.5 X 6.0 cm) of DEAE-Sephadex A-50, were eluted s...

متن کامل

Simultaneous separation of serum creatine kinase and lactate dehydrogenase isoenzymes by ion-exchange column chromatography.

Lactate dehydrogenase isoenzymes were partially separated by use of a previously described column technique for creatine kinase [Clin. Chem. 20, 36 (1974)]. Extracts of lactate dehydrogenase-rich tissues were used to evaluate column resolution. Samples layered on mini-columns containing DEAE-Sephadex were eluted with Tris-buffered sodium chloride (100 and 200 mmol/liter). Lactate dehydrogenase ...

متن کامل

Creatine kinase isoenzyme MB determination on the ACA: dependence on serum matrix and other effectors.

Creatine kinase isoenzyme MB catalytic activities in human serum, determined by ACA ion exchange chromatography and immunoinhibition, differ significantly, the correlation coefficient being 0.88. The reasons for this variation are interference of antibodies with the creatine kinase B subunit in the immunoinhibition assay, nonreproducible elution of creatine kinase isoenzyme MB from the ion exch...

متن کامل

Rapid assessment of isoenzymes by high-performance liquid chromatography.

We describe the rapid profiling of isoenzymes by use of microparticulate anion-exchange chromatography supports and a continuous, post-separation enzyme detector in a high-performance liquid chromatograph. Chromatographic analysis and enzyme detection are fully automated and provide excellent reproducibility. Factors affecting the isoenzyme profile and detector response characteristics are asse...

متن کامل

Macro creatine kinase BB in serum, and some data on its prevalence.

We report the case of a patient with persistently above-normal activity of creatine kinase (CK) in serum, a major fraction of which on electrophoresis moved as a band between the MM and MB isoenzymes and on anion-exchange column chromatography eluted in the MB fraction. Measurements in the presence of specific M or B subunit-inhibitory antibodies indicated that 93% of the activity consisted of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1977