Experimental Investigation on Pore Structure Characterization of Concrete Exposed to Water and Chlorides

نویسندگان

  • Jun Liu
  • Kaifeng Tang
  • Qiwen Qiu
  • Dong Pan
  • Zongru Lei
  • Feng Xing
چکیده

In this paper, the pore structure characterization of concrete exposed to deionised water and 5% NaCl solution was evaluated using mercury intrusion porosity (MIP), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The effects of calcium leaching, fly ash incorporation, and chloride ions on the evolution of pore structure characteristics were investigated. The results demonstrate that: (i) in ordinary concrete without any fly ash, the leaching effect of the cement products is more evident than the cement hydration effect. From the experimental data, Ca(OH)₂ is leached considerably with the increase in immersion time. The pore structure of concrete can also be affected by the formation of an oriented structure of water in concrete materials; (ii) incorporation of fly ash makes a difference for the performance of concrete submersed in solutions as the total porosity and the pore connectivity can be lower. Especially when the dosage of fly ash is up to 30%, the pores with the diameter of larger than 100 nm show significant decrease. It demonstrates that the pore properties are improved by fly ash, which enhances the resistance against the calcium leaching; (iii) chlorides have a significant impact on microstructure of concrete materials because of the chemical interactions between the chlorides and cement hydrates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature

This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...

متن کامل

INVESTIGATION ON THE MIXTURE OF CALCIUM AND AMMONIUM NITRATES AS STEEL CORROSION INHIBITOR IN SIMULATED CONCRETE PORE SOLUTION

Abstract: Despite having a number of advantages, reinforced concrete can suffer rebar corrosion in high–chloride media, resulting in failure of reinforced concrete structures. In this research the corrosion inhibition capability of the mixture of calcium and ammonium nitrate of steel rebar corrosion was investigated in the simulated concrete pore solution. Cyclic polarization and Electroche...

متن کامل

The study of effective stress and pore water pressures in the foundation of a concrete gravity platform affected by loads due to waves, currents and wind in the Persian Gulf

It is proposed to use a single base platform in the Persian Gulf considering its low depth and more appropriate environmental conditions in comparison to North Sea and Mexico Gulf where this kind of platform is very popular. The pile of platform is responsible for transmission of environmental loads resulted from waves, currents, wind and dead loads to foundation of platform. Using SACS 5.3 sof...

متن کامل

An Investigation of Coarse Aggregate, Water-Cement Ratio, and Silika Fume on Frost Resistance of HS Concrete

It is well known that the characteristics of concrete components greatly affect the durability of high strength/high performance (HS/HP) concrete against frost action. Undoubtedly, precise recognition of this relationship leads to appropriate selection of the type and proportions of concrete components in any particular project. In the current study, the aim is to investigate the possibility ...

متن کامل

An Investigation of Coarse Aggregate, Water-Cement Ratio, and Silika Fume on Frost Resistance of HS Concrete

It is well known that the characteristics of concrete components greatly affect the durability of high strength/high performance (HS/HP) concrete against frost action. Undoubtedly, precise recognition of this relationship leads &#10to appropriate selection of the type and proportions of concrete components in any particular project. In the current study, the aim is to investigate the possibilit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014