BACKGROUND Multi-channel recording of surface electromyographyic (EMG) signals is very likely to be contaminated by electrocardiographic (ECG) interference, specifically when the surface electrode is placed on muscles close to the heart. METHODS A novel fast independent component analysis (FastICA) based peel-off method is presented to remove ECG interference contaminating multi-channel surface EMG signals. Although demonstrating spatial variability in waveform shape, the ECG interference in different channels shares the same firing instants. Utilizing the firing information estimated from FastICA, ECG interference can be separated from surface EMG by a "peel off" processing. The performance of the method was quantified with synthetic signals by combining a series of experimentally recorded "clean" surface EMG and "pure" ECG interference. RESULTS It was demonstrated that the new method can remove ECG interference efficiently with little distortion to surface EMG amplitude and frequency. The proposed method was also validated using experimental surface EMG signals contaminated by ECG interference. CONCLUSIONS The proposed FastICA peel-off method can be used as a new and practical solution to eliminating ECG interference from multichannel EMG recordings.
منابع مشابه
Progressive FastICA Peel-Off and Convolution Kernel Compensation Demonstrate High Agreement for High Density Surface EMG Decomposition
Decomposition of electromyograms (EMG) is a key approach to investigating motor unit plasticity. Various signal processing techniques have been developed for high density surface EMG decomposition, among which the convolution kernel compensation (CKC) has achieved high decomposition yield with extensive validation. Very recently, a progressive FastICA peel-off (PFP) framework has also been deve...
متن کاملHigh-pass filtering to remove electrocardiographic interference from torso EMG recordings.
UNLABELLED Removal of electrocardiographic (ECG) contamination of electromyographic (EMG) signals from torso muscles is often attempted by high-pass filtering. This study investigated the effects of the cut-off frequency used in this high-pass filtering technique on the resulting EMG signal. Surface EMGs were recorded on five subjects from the rectus abdominis, external oblique, and erector spi...
متن کاملCorrigendum to: “Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique†published in J Biomed Phys Eng 2014; 4(1):31-38
متن کامل
Complexity Analysis of Surface EMG for Overcoming ECG Interference toward Proportional Myoelectric Control
Electromyographic (EMG) signals from muscles in the body torso are often contaminated by electrocardiography (ECG) interferences, which consequently compromise EMG intensity estimation. The ECG interference has become a barrier to proportional control of myoelectric prosthesis using a neural machine interface called targeted muscle reinnervation (TMR), which involves transferring the residual a...
متن کاملRemoving ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...