P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: the microfocus endstation

نویسندگان

  • Adeline Buffet
  • André Rothkirch
  • Ralph Döhrmann
  • Volker Körstgens
  • Mottakin M. Abul Kashem
  • Jan Perlich
  • Gerd Herzog
  • Matthias Schwartzkopf
  • Rainer Gehrke
  • Peter Müller-Buschbaum
  • Stephan V. Roth
چکیده

The P03 beamline, also called the microfocus and nanofocus X-ray scattering (MiNaXS) beamline, exploits the excellent photon beam properties of the low-emittance source PETRA III to provide a microfocused/nanofocused beam with ultra-high intensity for time-resolved X-ray scattering experiments. The beamline has been designed to perform X-ray scattering in both transmission and reflection geometries. The microfocus endstation started user operation in May 2011. An overview of the beamline status and of some representative results highlighting the performance of the microfocus endstation at MiNaXS are given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ID23-2 structural biology microfocus beamline at the ESRF

The first phase of the ESRF beamline ID23 to be constructed was ID23-1, a tunable MAD-capable beamline which opened to users in early 2004. The second phase of the beamline to be constructed is ID23-2, a monochromatic microfocus beamline dedicated to macromolecular crystallography experiments. Beamline ID23-2 makes use of well characterized optical elements: a single-bounce silicon (111) monoch...

متن کامل

Beamline P02.1 at PETRA III for high-resolution and high-energy powder diffraction

Powder X-ray diffraction techniques largely benefit from the superior beam quality provided by high-brilliance synchrotron light sources in terms of photon flux and angular resolution. The High Resolution Powder Diffraction Beamline P02.1 at the storage ring PETRA III (DESY, Hamburg, Germany) combines these strengths with the power of high-energy X-rays for materials research. The beamline is o...

متن کامل

Upgrade of the small-angle X-ray scattering beamline X33 at the European Molecular Biology Laboratory, Hamburg

The small-angle X-ray scattering beamline X33 of the European Molecular Biology Laboratory (EMBL) at the DORIS III storage ring [Deutsches Elektronen Synchrotron (DESY) Hamburg] was used for more than two decades to study the structure of non-crystalline biological systems. During recent years the beamline’s scope has changed and is now predominantly used to analyze solutions of biological macr...

متن کامل

Study of the Microfocus X-Ray Tube Based on a Point-Like Target Used for Micro-Computed Tomography

For a micro-Computed Tomography (Micro-CT) system, the microfocus X-ray tube is an essential component because the spatial resolution of CT images, in theory, is mainly determined by the size and stability of the X-ray focal spot of the microfocus X-ray tube. However, many factors, including voltage fluctuations, mechanical vibrations, and temperature changes, can cause the size and the stabili...

متن کامل

Transmission-type microfocus x-ray tube using carbon nanotube field emitters

A microfocus x-ray tube that can generate x rays with the focal spot size less than 5 m has been demonstrated using carbon nanotube CNT field emitters. A CNT cathode on a sharp tungsten tip, a magnetic solenoid lens, and a transmission-type x-ray target were adopted for the microfocus x-ray tube. The design characteristics and the operation performance of the microfocus x-ray tube are presented...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2012