Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

نویسندگان

  • M S Norell
  • J P Lyons
  • A H Gershlick
  • J E Gardener
  • M T Rothman
  • C A Layton
  • R Balcon
چکیده

Left ventricular performance during percutaneous transluminal coronary angioplasty was assessed in 52 patients by intravenous digital subtraction ventriculography. After injection of contrast into the right atrium ventriculograms were obtained before and during balloon inflation. In 37 patients they were also obtained after the procedure. A 12 lead electrocardiogram was monitored throughout. During balloon inflation the left ventricular ejection fraction fell (from 73% to 57%) in all but one patient; the decreases in patients with single vessel or multivessel disease were similar. The fall in left ventricular ejection fraction during percutaneous transluminal coronary angioplasty of the left anterior descending artery (19%) was significantly greater than that during balloon inflation in the right coronary (10%) or circumflex (8%) coronary arteries. It also reduced anterobasal, anterior, and apical segmental shortening while right coronary percutaneous transluminal coronary angioplasty affected inferior and apical segments. In 33 (63%) patients the ST segment was altered during balloon inflation. The fall in left ventricular ejection fraction correlated significantly with the magnitude of both ST segment elevation (r = 0.637) and ST depression (r = 0.396). Left ventricular ejection fraction and regional wall motion returned to baseline values after the procedure. Balloon inflation during percutaneous transluminal coronary angioplasty produces considerable abnormalities of global and regional left ventricular performance and this indicates the presence of myocardial ischaemia, which may not be apparent on electrocardiographic monitoring. Intravenous digital subtraction ventriculography is useful for monitoring left ventricular performance during controlled episodes of coronary occlusion produced by balloon inflation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of left ventricular function and contractile reserve after successful recanalization by thrombolysis versus rescue percutaneous transluminal coronary angioplasty for acute myocardial infarction.

To determine how coronary reperfusion affects rest and exercise ventricular function after acute myocardial infarction (AMI), 63 patients with a patent infarct artery after intravenous thrombolytic therapy (lysis) were compared with 27 patients who failed thrombolysis but had successful acute recanalization by percutaneous transluminal coronary angioplasty (PTCA) as a "rescue" procedure. Contra...

متن کامل

[Aneurysm-like wall motion abnormality in hibernating myocardium detected by stress thallium scintigraphy].

A 70-year-old female patient presented and ECG with QS patterns and ST elevation in V1-3. Left ventriculography showed severely abnormal wall motion of the anteroseptal similar to a left ventricular aneurysm. Based on previous experience that 201Tl myocardial scintigraphy revealed possible myocardial viability in a patient with left ventricular aneurysm suspected of having apparently no myocard...

متن کامل

Protective effect of collateral vessels during coronary angioplasty.

To assess the potential protective role of collateral vessels 27 patients undergoing angioplasty of the left anterior descending coronary artery were studied by intravenous digital subtraction left ventriculography. Fifteen patients had no collateral vessels (group 1) and 12 had some degree of collateral supply (group 2). During balloon inflation ST segment elevation in group 1 (4.9 mm) was sig...

متن کامل

Diastolic aortic pressure rise during percutaneous transluminal coronary angioplasty: an index of left ventricular systolic dysfunction.

OBJECTIVES To investigate the relation between diastolic aortic pressure response and left ventricular systolic dysfunction during percutaneous transluminal coronary angioplasty. BACKGROUND The abnormal diastolic blood pressure rise during exercise in patients with coronary artery disease probably reflects left ventricular systolic dysfunction rather than the number of stenosed coronary arter...

متن کامل

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 1988