Advanced LSI-based amperometric sensor array with light-shielding structure for effective removal of photocurrent and mode selectable function for individual operation of 400 electrodes.
نویسندگان
چکیده
We have developed a large-scale integrated (LSI) complementary metal-oxide semiconductor (CMOS)-based amperometric sensor array system called "Bio-LSI" as a platform for electrochemical bio-imaging and multi-point biosensing with 400 measurement points. In this study, we newly developed a Bio-LSI chip with a light-shield structure and a mode-selectable function with the aim of extending the application range of Bio-LSI. The light shield created by the top metal layer of the LSI chip significantly reduces the noise generated by the photocurrent, whose value is less than 1% of the previous Bio-LSI without the light shield. The mode-selectable function enables the individual operation of 400 electrodes in off, electrometer, V1, and V2 mode. The off-mode cuts the electrode from the electric circuit. The electrometer-mode reads out the electrode potential. The V1-mode and the V2-mode set the selected sensor electrode at two different independent voltages and read out the current. We demonstrated the usefulness of the mode-selectable function. First, we displayed a dot picture based on the redox reactions of 2.0 mM ferrocenemethanol at 400 electrodes by applying two different independent voltages using the V1 and V2 modes. Second, we carried out a simultaneous detection of O2 and H2O2 using the V1 and V2 modes. Third, we used the off and V1 modes for the modification of the osmium-polyvinylpyridine gel polymer containing horseradish peroxidase (Os-HRP) at the selected electrodes, which act as sensors for H2O2. These results confirm that the advanced version of Bio-LSI is a promising tool that can be applied to a wide range of analytical fields.
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملGraphene Oxide/Polyaniline-Based Multi Nano Sensor for Simultaneous Detection of Carbon Dioxide, Methane, Ethanol and Ammonia Gases
In this study, a multi nanosensor was fabricated for the simultaneous detection of carbon dioxide, methane, ethanol, and ammonia gases, and its electrochemical response to various concentrations of these gases were investigated. In order to fabricate this multi nanosensor, in the first phase, the Graphene-Oxide/Polyaniline (GO/PANI) nanocomposite was synthesized. Chemical ...
متن کاملA Dual-Mode CMOS Imager for Free-Space Optical Communication with Signal Light Source Tracking and Background Cancellation
This paper presents a dual-mode CMOS imager with free-space optical communication capability for augmented reality application. The proposed imager implements two operation modes as imaging mode and communication mode on a single sensing array. In imaging mode, the sensing pixel output raw image data based on the conventional integration-and-readout operation. In communication mode, the locatio...
متن کاملLsi-based Amperometric Chip Device with 400 Sensors for Detection of Alkaline Phosphatase and Respiration Activities of Embryonic Stem Cells
In this present study, we fabricated an LSI-based amperometric chip device with highly temporal and spacial resolution for electrochemical imaging, applied to detection of alkaline phosphatase (ALP) activity and respiration activity of embryonic stem (ES) cells.
متن کاملSimulation Analysis of Positional Relationship between Embryoid Bodies and Sensors on an LSI-based Amperometric Device for Electrochemical Imaging of Alkaline Phosphatase Activity.
In the present study, we monitored the alkaline phosphatase (ALP) activity of embryoid bodies (EBs) of mouse embryonic stem (ES) cells using a large-scale integration (LSI)-based amperometric device with 400 sensors and a pitch of 250 μm. In addition, a simulation analysis was performed to reveal the positional relationship between the EBs and the sensor electrodes toward more precise measureme...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2015