Intrapelvic protrusion of the ceramic head resulting from forte ceramic liner fracture without a significant trauma: a case report.
نویسندگان
چکیده
In this article, we present a 48-year-old female case who had an unsuccessful previous forte ceramic-on-ceramic total hip arthroplasty for early coxarthrosis secondary to acetabular dysplasia. She had fracture and protrusion of the ceramic liner through the titanium acetabular shell without any apparent trauma, possibly resulting from the mistake during the implantation of the ceramic liner into the metal shell in the initial operation. The patient had no other risk factors (component malposition, trauma, malalignment) for ceramic liner fracture. She underwent revision surgery with allograft, reinforcement ring, all-polyethylene cup and reinforced stainless-steel femoral head.
منابع مشابه
Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component
The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...
متن کاملFracture of Ceramic Liner and Head in a Total Hip Arthroplasty with a Sandwich Type Cup
Due to its advantages, ceramic-on-ceramic bearings have been widely used in young patients for almost 30 years. Long-term survivorship, low wear, and low biological reactivity to particles are some of its characteristics. Even though this material has had a lot of improvements, the risk of fracture is one of the concerns. There have been reports of fracture of ceramic in the acetabular liner an...
متن کاملRepeated Ceramic Head Fracture after Ceramic-on-ceramic Total Hip Arthroplasty
Early generation ceramic articulations were problematic in terms of ceramic implant fracture and wear. Although the mechanical properties of ceramic material have improved during the last three decades, ceramic component fracture remains an issue. Many authors have reported fractures of the ceramic head, and a few have described ceramic acetabular insert fracture. However, these complications a...
متن کاملWear of a composite ceramic head caused by liner fracture.
Third-generation composite ceramics (eg, Delta; DePuy Orthopaedics, Warsaw, Indiana; Ceramtec, Plochingen, Germany) have greatly improved material characteristics compared with second-generation products. This case report presents a patient after total hip arthroplasty with a fractured ceramic liner and a heavily worn ceramic head (both third-generation ceramics) retrieved 9 months after surger...
متن کاملIsolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.
BACKGROUND While most reports of component fracture following alumina-on-alumina total hip arthroplasty have involved the acetabular liner, few have involved fracture of the alumina femoral head. In the present multicenter study, we investigated ceramic head fractures in a cohort of patients who underwent third-generation alumina-on-alumina total hip arthroplasty. METHODS We performed a retro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2013