AbstractID: 6000 Title: MRI Relaxometry BMD Measurements using Conventional Phase Symmetrized Rapid Increased Flip Spin Echo and Standard Gradient Echo and its correlation with DXA

ثبت نشده
چکیده

ID: 6000 Title: MRI Relaxometry BMD Measurements using Conventional Phase Symmetrized Rapid Increased Flip Spin Echo and Standard Gradient Echo and its correlation with DXA Purpose: Recently, several special MRI protocols have been developed for BMD measurements for deriving R2(=1/T2), R2*(=1/T2*) and R2'(=R2*-R2) applied in several cross sectional studies. But, due to high slew rate gradients with high amplitudes in small periods, such protocols can be used only in system with high slew rate (22 mT/m.s or greater). However, our main aim in this study was to develop optimized versions of standard GE and conventional SE protocols using in existing MRI systems for BMD measurements, as most systems do not support such newly high slew rate protocols. Method and Materials: This study was performed by 1.5T-MRI system(Picker Vista-Q800, slew rate=13mT/m.s), SNR phantom (1.25g/l CuSO4, T2=200ms) for calibration, a body RF-Coil, cross sectional study with 12 normal, 12 osteopenia, 12 osteoporosis volunteers done with a Lunar DXA system-(DPX-MD). To determine R2* and R2, simple standard-GE and conventional phasesymmetrized-rapid-increased-flip-SE(PRISE) protocols with different TE/TR were applied. Then in coronal section of femoral-neck, relaxation rates were compared with BMD from DXA. The optimized conditions of the protocols for R2* measurement standard-GE protocol with TE=13.42/18/26.8ms, TR=800ms and ST=8mm(CV(R2*)=2.96%) and for R2 measurement PRISE protocol with TE=36/54/63/72ms, TR=800ms and ST=8mm(CV(R2)=3%), receiver bandwidth of 21.2 kHz for PRISE, 31.75kHz for GE, Matrix=190x256, FOV=45cm leading to good SNR. Results: The overall Pearson's correlation coefficient of R2*, R2' and R2 vs. BMD were calculated as 0.62(p<0.003), 0.62(p<0.003) and 0.03(p<0.9), respectively. Based on the R2* and R2' parameters, significant difference between normal and abnormal groups (osteopenia and osteoporosis) were found. However, there was no significant difference between osteopenia and osteoporosis groups using the relaxation parameters. Conclusion: R2* and R2' showed a significant positive correlation with BMD. Therefore, in accordance with DXA values, the results showed standard-GE and conventional-SE(PRISE) could be proper protocols for BMD-measurements in femoral-neck even in low slew rates systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

تعیین پروتکل بهینه جهت اندازه گیری میزان تراکم استخوان با استفاده از MRI Relaxometry و مقایسه نتایج حاصل با تکنیک DEXA

Introduction & Objective : The aim of this study was to optimize MRI conventional protocols for BMD(Bone Mineral Density) measurements using MRI Relaxometry in systems not facilitated with special multi echo protocols. Since, cortical and trabecular bone separation can not be performed in DEXA, so the results might lead to erroneous interpretation of BMD values. One method for bone quality dete...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Reliable Cortical Thickness Estimation with Reduction of Susceptibility-Induced Signal Loss using Optimized T1-Weighted Single-Slab 3D Turbo Spin Echo Pulse Sequence

Introduction: In brain volumetry, magnetization-prepared rapid gradient recalled echo (MP-RAGE) imaging [1], which yields a strong T1-weighted contrast among brain tissues and thus a highly accurate segmentation of the brain structures, has been widely used. However, since signals in MPRAGE result from free induction decay (FID) without radio-frequency (RF) pulse induced refocusing, conventiona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006