Computer-aided surface estimation of pain drawings – intra- and inter-rater reliability
نویسندگان
چکیده
Pain drawings are often utilized in the documentation of pain conditions. The aim here was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings consecutively, using the computer program Quantify One. Forty-eight patients with chronic nonmalignant pain had shaded in their experienced pain on the front and back views of a pain drawing. The templates were scanned and displayed on a 17-inch computer screen. Two independent examiners systematically encircled the shaded-in areas of the pain drawings with help of a computer mouse, twice each on two separate days, respectively. With this method it is possible to encircle each marked area and to obtain immediate details of its size. The total surface area (mm(2)) was calculated for each pain drawing measurement. Each examiner measured about 2400 areas, and as a whole, the number of areas measured varied only by 3%. The intra-rater reliability was high with intraclass correlation coefficients 0.992 in Examiner A and 0.998 in Examiner B. The intra-individual absolute differences were small within patients within one examiner as well as between the two examiners. The inter-rater reliability was also high. Still, significant differences in the absolute mean areas (13%) were seen between the two examiners in the second to fourth measurement sessions, indicating that one of the examiners measured systematically less. The measurement error was ≤10%, indicating that use of the program would be advantageous both in clinical practice and in research, but if repeated, preferably with the same examiner. Since pain drawings with this method are digitized, high quality data without loss of information is possible to store in electronic medical records for later analysis, both regarding precise location and size of pain area. We conclude that the computer program Quantify One is a reliable method to calculate the areas of pain drawings.
منابع مشابه
Inter and intra-rater repeatability of the scoring of foot pain drawings
BACKGROUND Foot pain drawings (manikins) are commonly used to describe foot pain location in self-report health surveys. Respondents shade the manikin where they experience pain. The manikin is then scored via a transparent overlay that divides the drawings into areas. In large population based studies they are often scored by multiple raters. A difference in how different raters score manikins...
متن کاملReliability of ultrasound in combination with surface electromyogram for evaluating the activity of abdominal muscles in individuals with and without low back pain
This study investigated the reliability of ultrasound in combination with surface electromyogram (EMG) for evaluating the activity of the abdominal muscles in individuals with and without low back pain during the abdominal drawing-in maneuver (ADIM). The study recruited ten individuals with or without low back pain, respectively. While the participants were performing the ADIM, the activities o...
متن کاملEvaluation of Spasticity Using the Ashworth Scale with Intermediate Scores (ASIS)
Objectives: The main purpose of this research was to study and contribute to an accurate test of spastic limb. The intra, inter rater reliability of the test was examined. Methods: The present study was carried out in two parts In the first part of the study, the modified Ashworth Scale with Intermediate Scores (ASIS) was studied. During the second part of the study the intra, inter rater re...
متن کاملThe reliability of an easy measuring method for abutment convergence angle with a computer-aided design (CAD) system
PURPOSE The purpose of this study was to evaluate the intra-rater reliability and inter-rater reliability of three different methods using a drawing protractor, a digital protractor after tracing, and a CAD system. MATERIALS AND METHODS Twenty-four artificial abutments that had been prepared by dental students were used in this study. Three dental students measured the convergence angles by e...
متن کاملIntra- and inter-rater reliability of neutral head position and target head position tests in patients with and without neck pain
BACKGROUND Cervical proprioception is a common term used in neck rehabilitation, and it is examined using neutral head position (NHP) and target head position (THP) tests. OBJECTIVE To investigate intra- and inter-rater reliability of the NHP and THP tests in patients with neck pain and in healthy controls. METHODS The intra-rater (between-day) and inter-rater (within-day) reliability of th...
متن کامل