Static lung volumes in healthy subjects assessed by helium dilution during occlusion of one mainstem bronchus.

نویسندگان

  • B Johansen
  • O Bjørtuft
  • J Boe
چکیده

BACKGROUND Single lung function is usually assessed by radioisotopes or, more rarely, by bronchospirometry in which a double lumen catheter is used to separate ventilation of the two lungs. The latter is more precise but less comfortable. An alternative bronchoscopic method is described for determining the volume of a single lung. METHODS One mainstem bronchus was temporarily occluded with an inflatable balloon during fibreoptic bronchoscopy in 12 healthy volunteers aged 18-29 years. The functional residual capacities (FRC) of the right, left, and both lungs were measured in duplicate by closed circuit helium dilution. Supplementary vital capacity (VC) manoeuvres permitted calculation of single lung capacities (TLC) and residual volumes (RV). RESULTS The standard deviation of a single determination of capacities of the right, left, and both lungs were: TLC, 80, 96, and 308 ml; VC, 56, 139, 171 ml; FRC, 131, 74, and 287 ml; RV, 112, 185, and 303 ml, respectively. The sum of the right and left unilateral TLC was not different from bilateral TLC (6.12 v 5.95 l) and the sum of the unilateral FRC was not different from the bilateral FRC (2.60 v 2.78 l). The sum of the unilateral VC was lower than bilateral VC (4.52 v 4.80 l), that of the unilateral RV was higher than bilateral RV (1.60 v 1.16 l). For all subdivisions of lung volume, the right lung was larger than the left. The most common complaint was substernal discomfort during complete exhalation. Oxygen saturation rarely fell below 90%. CONCLUSIONS Temporary occlusion of a mainstem bronchus in normal subjects is safe, relatively simple, and allows fairly precise and accurate measurements of unilateral static lung volumes. Occlusion at TLC, however, probably prevents proper emptying of the non-occluded lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of helium dilution and plethysmographic lung volumes in pregnant women.

The multibreath helium equilibration method is the technique recommended for routine measurement of static lung volumes in normal subjects. However, pregnancy could be an exception to this general rule, due to airway closure during the second half of gestation. The aim of this study was to compare the measurements of lung volumes by plethysmography and helium dilution during pregnancy. Twenty t...

متن کامل

Critical evaluation of computerised x ray planimetry for the measurement of lung volumes.

BACKGROUND Computerised x-ray planimetry has been advocated as an alternative to body plethysmography and helium dilution for measuring static lung volumes. The accuracy and reproducibility of this method has been assessed in comparison with these standard methods. METHODS Plethysmographic and planimetric measurements of total lung capacity (TLC) and functional residual capacity (FRC) were ma...

متن کامل

Mechanical coupling between the hemithoraces in humans.

Unilateral airway occlusion permits measurement of single lung function. Since the results suggest that the occluded lung influences the mobility of the contralateral hemithorax, we wanted to test this hypothesis. In eight healthy subjects, we measured, using computed tomography, lung parenchymal area and inner rib cage parasagittal and transverse diameters at three different levels and at maxi...

متن کامل

Lung volumes measured by the forced rebreathing technique in children with airways obstruction.

Forced rebreathings may recruit trapped gas into the mixing process. Therefore, we assessed the validity and reproducibility of measurements of residual volume (RVN2) by forced rebreathing in a closed circuit using N2 as indicator gas (N2FR) in children with airways obstruction. Validity was studied from measurements of RV obtained by N2FR, by helium dilution during resting ventilation, and by ...

متن کامل

Left mainstem bronchial rupture during one-lung ventilation with Robertshaw double lumen endobronchial tube -A case report-

Lung separation using a double-lumen endobronchial tube is necessary for video assisted thoracoscopy (VATs). Bronchial rupture after intubation with a double-lumen endobronchial tube has been rarely reported. We report a case of a 70-year-old man who had solitary pulmonary nodule in his right upper lobe. He was intubated with a left-sided Robertshaw double-lumen endobronchial tube. He underwent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 1993