Analytical evaluation of the Diazyme glycated serum protein assay on the siemens ADVIA 1800: comparison of results against HbA1c for diagnosis and management of diabetes.

نویسندگان

  • Karina Rodriguez-Capote
  • Kayla Tovell
  • Deborah Holmes
  • Janice Dayton
  • Trefor N Higgins
چکیده

Hemoglobin A1c (HbA1c) is considered the gold standard for assessment of glycemic control in diabetic patients. HbA1c is inadequate in individuals homozygous or compound heterozygous for hemoglobin variants or in conditions with an altered red blood cell turnover. In these cases glycated albumin (GA) is proposed as an alternative assay. We aimed to evaluate the analytical performance of the Diazyme glycated serum protein (GSP) assay on an automated analyzer, to establish a reference interval (RI), and to compare from a clinical perspective, GSP/GA with glycated Hb (glyHb) results. Validation studies followed the CLSI guidelines and included precision, linearity, interferences, concordance of results with glyHb, and RI calculation. GSP was analyzed on representative samples with previously ordered HbA1c and albumin from the Dyna LIFE : DX laboratory. Samples from patients with bisalbuminemia, hemoglobinopathies, and multiple myeloma were also included. Within-run and total imprecision was <3.0% at both levels of control, analytical sensitivity was 5.31 μmol/L, and linearity was verified from 10 to 1150 μmol/L (total allowable error of 5%). Clinical concordance between %GA and glyHb was substantial (n = 175, R2 = .91, kappa = .78, P = .167). GSP RI was 160 to 340 μmol/L or if expressed as %GA 10.5 to 17.5%. Analytical performance of the Diazyme GSP assay on the Siemens ADVIA 1800 is acceptable for clinical use. The RI obtained was higher than that suggested by the manufacturer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum biomarkers for assessing glycemic control in diabetes mellitus

Clinical evidence has revealed the association between complications Diabetes Mellitus (DM) and serum glycemic control. Thus, evaluation of the glycemic control status is crucial in the management of DM. Hemoglobin A1c (HbA1c) is the most common method for monitoring serum glycemic control. However, several confounding factors including red blood cell lifespan and hemoglobinopathies can affect ...

متن کامل

Correlation between Glycated Hemoglobin, Serum Glucose and Serum Lipid Levels in Type 2 Diabetes

Abstract Objective: Diabetes mellitus is the most common metabolic disease. One of the most common problems in diabetic patients is atherosclerotic cardiovascular disease which is induced by hyperlipidemia. Impaired lipid metabolism resulting from uncontrolled hyperglycemia has been implicated in cardiovascular complications in diabetic patients. Also, glycated hemoglobin (HbA1c) has been rega...

متن کامل

Trend of Changes in Blood Sugar and Glycated Hemoglobin in Electronic Health Records, Sari, Iran 2012- 2018

Background and purpose: High prevalence of Type 2 Diabetes Mellitus (T2DM) and its demand for regular care have resulted in a massive amount of electronic health records (EHRs). Hemoglobin A1c (HbA1c) and Fasting Blood Sugar (FBS) levels are two widely-used diagnostic measures for evaluation of diabetes care. This study aimed at assessing Family Medicine Plan (FMP) and exploring the trend of ch...

متن کامل

Multicenter comparison of automated procalcitonin immunoassays

OBJECTIVES A multicenter study to compare results of BRAHMS Kryptor PCT with those obtained using four BRAHMS-partnered procalcitonin (PCT) automated immunoassays (DiaSorin Liaison, BioMérieux Vidas, Roche Cobas E601 and Siemens Advia Centaur) and the Diazyme immunotubidimetric assay implemented on four clinical chemistry platforms (Abbott Architect c16000, Siemens Advia 2400, Roche Cobas C501 ...

متن کامل

Analytical evaluation of Diazyme procalcitonin (PCT) latex-enhanced immunoturbidimetric assay on Beckman Coulter AU5800.

BACKGROUND This study was aimed to evaluate the analytical performance of the novel Diazyme procalcitonin (PCT) immunoturbidimetric assay on Beckman Coulter AU5800. METHODS Diazyme PCT is a latex-enhanced immunoturbidimetric assay, developed for use on laboratory instrumentations with capability of reading absorbance at 600 nm. This analytical evaluation included the assessment of limit of bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2015