Validation of a blood-sampling method for the measurement of 99mTc-methylene diphosphonate skeletal plasma clearance.
نویسندگان
چکیده
UNLABELLED Quantitative studies of bone using (99m)Tc-methylene diphosphonate (MDP) reflect bone remodeling. The simplest method of evaluating (99m)Tc-MDP kinetics involves taking multiple blood samples and measuring total clearance (K(total)) from the area under the plasma curve (AUC) and deriving bone clearance (K(bone)) by subtracting glomerular filtration rate (GFR) from K(total). However, the accuracy of the AUC method is uncertain because of assumptions that the terminal exponential is reached by 2 h and that the rate constant k(4), representing the backflow of tracer from bone to plasma, is negligibly small. The aim of this study was to validate the accuracy of the AUC method by comparing K(bone) values obtained by that method with those obtained by gamma-camera imaging. METHODS Seventy-one patients were injected with 600 MBq of (99m)Tc-MDP. For the first 22 patients, whole-body images were acquired at 15 min and at 1, 2, 3, and 4 h after injection, whereas the remaining 49 were imaged at 15 min and at 1 and 3 h. Two-minute static images of the thighs were acquired immediately before each whole-body scan. Multiple blood samples were taken between 5 min and 4 h, and free (99m)Tc-MDP was measured using ultrafiltration. Two gamma-camera methods were used to evaluate K(bone): the Patlak plot method and the Brenner method, which is based on measuring soft-tissue uptake in the thighs. The soft-tissue data were also used to measure k(4). RESULTS The soft-tissue data gave a k(4) value of 0.0003 min(-1) (95% confidence interval, 0-0.0008 min(-1)). The mean (+/-SD) (99m)Tc-MDP K(bone) was 56.0 +/- 32.4 mL x min(-1) with the AUC method, 49.5 +/- 32.1 mL x min(-1) with the Patlak method, and 42.8 +/- 32.0 mL x min(-1) with the Brenner method. Correcting the AUC values of K(total) by factors of 0.95 and 0.90 gave K(bone) values in agreement with the Patlak and Brenner methods, respectively. CONCLUSION Values of k(4) are too small to affect values of K(bone) measured using the AUC method. Correcting K(total) by factors in the range of 0.90-0.95 corrects for the error in the terminal exponential and brings K(bone) values measured using the AUC method into agreement with the gamma-camera results.
منابع مشابه
A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]
Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...
متن کاملSPECT-CT for characterization of extraosseous uptake of 99mTc-methylene diphosphonate on bone scintigraphy.
Bone scintigraphy is a sensitive and popular method for imaging a wide array of benign or malignant skeletal abnormalities. However, the uptake of tracers used for bone scintigraphy may be observed in various extraosseous sites, thereby limiting its specificity. It is difficult to correctly localize such sites of uptake on planar bone scintigraphy alone. The addition of hybrid single-photon emi...
متن کاملQuantitative measurements of bone remodeling using 99mTc-methylene diphosphonate bone scans and blood sampling.
UNLABELLED Quantitative studies of bone using (99m)Tc-methylene diphosphonate ((99m)Tc-MDP) have a potentially valuable role in investigating the treatment of patients with metabolic bone disease. In this study we compared 3 different methods of measuring whole-skeleton (99m)Tc-MDP plasma clearance (K(bone)) in 12 osteoporotic postmenopausal women (mean age, 67.3 y) before participation in a cl...
متن کاملReversible pulmonary uptake and hypertrophic pulmonary osteoarthropathic distribution of technetium-99m methylene diphosphonate in a case of Pneumocystis carinii pneumonia.
Diffuse pulmonary deposition of [99mTc]methylene diphosphonate (MDP) as well as abnormalities characteristic of hypertrophic pulmonary osteoarthropathy have been observed in a patient with Pneumocystis carinii pneumonia (PCP). The findings of the bone scan together with those in the corresponding scintigraphy, and roentgenograms of the chest and skeletal structures are presented. Parallel rever...
متن کاملIncidental thyroid uptake during 99mTc-methylene diphosphonate bone scintigraphy in oncologic patients
Introduction: Extraosseous accumulation of 99mTc – methylene diphosphonate (MDP) may be due to neoplastic, dystrophic, hormonal, inflammatory, ischemic, traumatic or excretory disorders. 99mTc-MDP incidental thyroid uptake is not frequent and is possibly caused by the presence of dystrophic or metastatic calcification, biopsy procedure and presence of beni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 47 4 شماره
صفحات -
تاریخ انتشار 2006