Isolated polyethylene exchange versus acetabular revision for polyethylene wear.

نویسندگان

  • Camilo Restrepo
  • Elie Ghanem
  • Carrie Houssock
  • Mathew Austin
  • Javad Parvizi
  • William J Hozack
چکیده

UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessitate further surgery. We retrospectively reviewed 62 patients (67 hips) who underwent revision arthroplasty for polywear and osteolysis. Thirty-six hips had isolated polyethylene exchange, while 31 had full acetabular revision. The minimum followup was 2 years (mean, 2.8 years; range, 2-5 years). Three of 36 hips with a retained cup grafted through the cup holes failed within 5 years due to acetabular loosening. One of 31 hips with full revision underwent re-revision for aseptic cup loosening at 5 months postoperatively. Although we do not recommend prophylactic revision of all cups for polywear and osteolysis, the patient may be warned of the possibility of an approximate 10% failure rate when retaining the acetabular component. We do, however, advocate cup extraction in the following situations: damage to the locking mechanism, erosion of the femoral head through the liner and into the cup damaging the metal, and a malpositioned component that may jeopardize the stability of the revision. LEVEL OF EVIDENCE Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years.

BACKGROUND Hip resurfacing is an option to consider when treating younger, more active patients. Advantages over total hip arthroplasty include a more normal gait and a lower incidence of thigh pain. METHODS In this prospective study, 190 hip resurfacing procedures (164 participants) were performed using a cobalt-chromium femoral component and a cementless acetabular cup with a 3.8-mm highly ...

متن کامل

Comparison of Polyethylene Wear before and after Hip Revision with Liner Exchange Fixed with the Original Locking Mechanism

OBJECTIVE To compare the wear of conventional ultra-high molecular weight polyethylene (CUHMWPE) and highly cross-linked polyethylene (HCLPE) in hip revision with liner exchange fixed with original locking mechanism using analysis of history medical data. METHODS From Jan. 1, 2000, to Dec. 31, 2007, 26 patients (with 29 involved hips) underwent liner exchange revision fixed with the original ...

متن کامل

Evaluation of two surgical techniques for acetabular reconstruction in total hip replacement for congenital hip disease: results after a minimum ten-year follow-up.

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated betwe...

متن کامل

Cross-linked compared with historical polyethylene in THA: an 8-year clinical study.

UNLABELLED Wear particle-induced osteolysis is a major cause of aseptic loosening in THA. Increasing wear resistance of polyethylene (PE) occurs by increasing the cross-link density and early reports document low wear rates with such implants. To confirm longer-term reductions in wear we compared cross-linked polyethylene (irradiation in nitrogen, annealing) with historical polyethylene (irradi...

متن کامل

Catastrophic Failure of the Acetabular Polyethylene Liner in Ceramic-on-Polyethylene Total Hip Arthroplasty

INTRODUCTION Catastrophic polyethylene failure is a rare complication of ceramic-on-polyethylene total hip arthroplasty due to the favorable tribological characteristics of ceramic. Failure of the polyethylene liner can be disastrous, increasing periprosthetic osteolysis, metallosis, and risk of dislocation. Complications associated with ceramic-on-polyethylene articulations have been studied e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 467 1  شماره 

صفحات  -

تاریخ انتشار 2009