Serum LDH activities assayed spectrophotometrically by the “forward” (lactate + DPN to pyruvate + DPNH + H) method have linear reaction rates, activity proportional to the amount of serumadded,anda reproducibilityof 1.3%. The reagent mixtore can be stored frozen for 6 monthsand in the lyophilized state indefinitely. Poor separationof normal from abnormal serum LDH activities results from the nonlinearcalibrationcurves anddecreasingreaction rates of the “backward” spectrophotometric assay. The dinitrophenylhydrazinecolorimetric assay is deemed unsuitable for clinical use because largevariationsin activity result from minor variations in the reagent calibration curve, and because colorimetric activities are inaccurate as compared to activities obtained with the “forward” spectrophotometricassay.
منابع مشابه
Correlation of selected serum constituents: 1. Inter-individual variation and analytical error.
The intra-subject correlations of three clinically meaningful combinations of serum constituents--(a) potassium, calcium, and albumin; (b) urea, creatinine, and uric acid; and (c) aspartate aminotransferase, lactate dehydrogenase, and alkaline phosphatase--were studied in 11 healthy men. Duplicate serum samples were obtained at 800 h, 1100 h, and 1400 h on five different days. All assays were p...
متن کاملAutomated enzymatic assay for the determination of sucrose in serum and urine and its use as a marker of gastric damage.
1. Tozawa T. Enzyme-linked immunoglobulins and their clinical significance. Electrophoresis 1989;10:640–4. 2. Wroblewski F, LaDue JS. Lactic dehydrogenase activity in blood. Proc Soc Exp Biol Med 1955;90:210–3. 3. Kanno T, Maekawa M, Uchiyama S, Tsutiya S. Criteria for detection of heterozygous individuals with lactate dehydrogenase subunit deficiencies. Clin Chem 1990;36:178–9. 4. Fujita K. De...
متن کاملA response to "Serum-ethanol determination: comparison of lactate and lactate dehydrogenase interference in three enzymatic assays".
Gas chromatography is considered to be the reference method for ethyl alcohol determination. However, enzymatic ethanol assays have been developed for use in the clinical laboratory by several commercial vendors. Essentially, these assays utilize the oxidation of ethyl alcohol to acetaldehyde with concurrent reduction of nicotinamide adenine dinucleotide (NAD) to NADH while monitoring the incre...
متن کاملAn automated colorimetric (tetrazolium salt) assay for serum lactate dehydrogenase.
The adaptation of a tetrazolium salt assay for serum lactate dehydrogenase to full automation is described. The tetrazolium salt, INT, (2-p-iodophenyl-3-p-nitrophenyl5-phenyl tetrazolium chloride) serves as the chromogenic indicator of the enzyme activity. Phenazine methosulfate serves as an intermediate electron carrier. Estimation requires only 5 mm. of incubation, and assays may be run at th...
متن کاملCoupling of glucose-6-phosphate dehydrogenase and hemoglobin S screening to automated determinations of blood group and type.
1.Elliott, B. A., and Wilkinson, J. H., Serum “a-hydroxybutyrate dehydrogenase” in myocardial infarction and in liver disease. Lancet i, 698(1961). 2. Elliott, B. A., Jepson, E. M., and Wilkinson, J. H., Serum ahydroxybutyrate dehydrogenase-a new testwith improved specificity for myocardial lesions. Gun. Sci. 23, 305(1962). 3. Coodley, E. L., Evaluation of enzyme diagnosis in myocardial infarct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 12 شماره
صفحات -
تاریخ انتشار 1963