Shiley Flexible Adult Tracheostomy Tubes vs. Shiley DCT and FEN Tracheostomy Tubes

ثبت نشده
چکیده

Tracheostomy can influence the work of breathing by introducing additional resistance to airflow through the native airway. In a 1996 study, Hussey and Bishop determined that the presence of a deflated cuff in the airway significantly increased the work of breathing and theorized that a lower profile cuff would introduce less resistance to airflow. Hussey and Bishop also demonstrated that the presence of fenestration reduced the work of breathing. Interestingly, the authors noted that when they tested a cuffless No. 8 tube, the required inspiratory pressures remained below 1 cm of water at all flow rates. These findings suggest that the majority of the observed resistance to airflow for the cuffed tubes was due to the floppy, deflated cuff. In recent years, next-generation tracheostomy tubes with a taper-shaped cuff have been developed. Evidence to date suggests that a taper-shaped cuff provides a better seal against the tracheal wall at lower cuff pressures than a traditional cylindrical cuff, resulting in reduced fluid leak across the cuff and a lower potential for tracheal injury from excess pressure. 3 Given the influence of cuff shape and fenestration on tracheal airflow, the purpose of this analysis was to evaluate airflow around the tube for a range of ShileyTM tracheostomy tubes. More specifically, ShileyTM Flexible tracheostomy tubes with a taper-shaped TaperGuardTM cuff were compared to predicate tubes with cylindrical cuffs, with and without fenestration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro comparison of tracheostomy tube cuffs

INTRODUCTION The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may a...

متن کامل

Effect of repeated tracheostomy tube reprocessing on biofilm formation

OBJECTIVES/HYPOTHESIS To determine the effect of repeated reprocessing of pediatric tracheostomy tubes (TTs) on biofilm formation. STUDY DESIGN In vitro microbiological study. METHODS Pediatric, uncuffed, polyvinyl chloride (PVC) TTs from two different manufacturers (Tracoe Mini and Shiley) were reprocessed mechanically with household detergent and soaked in sodium hypochlorite (bleach). Tw...

متن کامل

Trach tubes designed to maximize safety may increase risk to ventilated patients

Dual-cannulae tracheostomy tubes with low-pressure cuffs, such as the Shiley LPC, are widely regarded as inherently safer than single lumen tubes with low-volume cuffs. For the patient who undergoes tracheostomy for failure to wean from mechanical ventilation, however, the insertion of a tube that occupies a large amount of space within the trachea can delay subsequent efforts to liberate him f...

متن کامل

Thrombotic occlusion of Bjork-Shiley prosthetic aortic valve.

Thrombotic occlusion of a prosthetic Bjork-Shiley valve is a potentially fatal complication. We present the case of a male, 62 years of age, diagnosed with thrombotic occlusion of prosthetic Bjork-Shiley aortic valve approximately 17 years post implantation. A brief review of the literature focusing on potential risk factors associated with the development of this condition and currently availa...

متن کامل

Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.

BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of ...

متن کامل