An evaluation of slot size in orthodontic brackets--are standards as expected?

نویسندگان

  • A C Cash
  • S A Good
  • R V Curtis
  • F McDonald
چکیده

The slots of five upper left central incisor brackets from 11 commercially available bracket systems (3M Unitek, Monrovia, Calif: Twin Torque Roth, Clarity MBT, and Victory Series MBT; Dentarum, Pforzheim, Germany: Discovery Roth (0.56 mm) and Elegance Plastic Roth; Forestadent, Pforzheim, Germany: Mini Mono MBT; TP LaPorte, Indiana: Nu-Edge Roth and Mxi Advant-Edge Roth; Ormco Corp., Orange, Calif: Damon II SL Roth; Ortho Organizers, San Marcos, Calif: Elite Mini Opti-MIM Roth and Elite Mini Opti-MIM MBT) were measured in the 0.022-inch (0.5588 mm) dimension. Measurements were taken after operator calibration, and a digital readout was produced. Results indicate that all bracket slots are oversized. Three bracket systems slots (Twin Torque, Clarity, and Mini Mono) were within 5% (+/-1.08, 1.655, 1.75) of their stated dimensions with essentially parallel slot walls. The Elegance Plastic slot was parallel sided but oversized by 12% (+/-1.15). The geometry of bracket slots was also variable. The Victory Series slot was slightly divergent with the top oversized by 6% (+/-1.035). The Nu-Edge slot was divergent and slot top oversized by 14% (+/-1.32). The Mxi Advant-Edge, Damon II SL, Elite Mini Opti-MIM Roth, and MBT were all convergent, and the base of the Damon slot was oversized by 17% (+/-1.79). The Discovery bracket was convergent, and the slot base was oversized by 24% (+/-1.255), which was the largest recorded variance. This bracket also had a 7% difference between the widths of the slot top and the base. Inaccurate machining of bracket slot dimensions and the use of undersized archwires may directly and adversely affect three-dimensional tooth positioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Orthodontic Bracket Manufacturing Tolerances and Dimensional Differences between Select Self-Ligating Brackets

In all manufacturing processes there are tolerances; however, orthodontic bracket manufacturers seldom state the slot dimensional tolerances. This experiment develops a novel method of analyzing slot profile dimensions using photographs of the slot. Five points are selected along each wall, and lines are fitted to define a trapezoidal slot shape. This investigation measures slot height at the s...

متن کامل

Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique

OBJECTIVE The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. METHODS Four types of ceramic ...

متن کامل

Torque expression in stainless steel orthodontic brackets. A systematic review.

OBJECTIVE To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and to analyze the limitations of the experimental methods used. MATERIALS AND METHODS In vitro studies measuring torque expression in conventional and self-ligating stainless steel brackets with a torque-measuring devi...

متن کامل

Effect of Pretreatment with Fluoride, Chlorhexidine, and Mixed Fluoride-Chlorhexidine Gels on Shear Bond Strength of Orthodontic Brackets: An Ex-Vivo Study

Background and Aim: Orthodontic patients are at an increased risk of caries due to difficulty in plaque control. Antimicrobial agents, such as fluoride and chlorhexidine, can be useful in preventing tooth demineralization. The present study aimed to determine the effect of fluoride and chlorhexidine gels and their mixture on the shear bond strength (SBS) of orthodontic brackets. Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Angle orthodontist

دوره 74 4  شماره 

صفحات  -

تاریخ انتشار 2004