Two orders of magnitude improvement in detection limit of lateral flow assays using isotachophoresis.

نویسندگان

  • Babak Y Moghadam
  • Kelly T Connelly
  • Jonathan D Posner
چکیده

Lateral flow immunoassays (LFA) are one of the most prevalent point-of-care (POC) diagnostics due to their simplicity, low cost, and robust operation. A common criticism of LFA tests is that they have poor detection limits compared to those of analytical techniques, like ELISA, which confines their application as a diagnostic tool. The low detection limit of LFA and associated long equilibration times are due to kinetically limited surface reactions that result from low target concentration. Here, we use isotachophoresis (ITP), a powerful electrokinetic preconcentration and separation technique, to focus target analytes into a thin band and transport them to the LFA capture line, resulting in a dramatic increase in the surface reaction rate and equilibrium binding. We show that ITP is able to improve the limit of detection (LoD) of LFA by 400-fold for 90 s assay time and by 160-fold for a longer 5 min time scale. ITP-enhanced LFA (ITP-LF) also shows up to 30% target extraction from 100 μL of the sample, whereas conventional LFA captures less than 1% of the target. ITP improves the LoD of LFA to the level of some lab-based immunoassays, such as ELISA, and may provide sufficient analytical sensitivity for application to a broader range of analytes and diseases that require higher sensitivity and lower detection limits.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanoparticle-based photoacoustic analysis for highly sensitive lateral flow assays.

This paper demonstrates a photoacoustics-based lateral flow test that takes advantage of the strong interaction of light and gold nanoparticles to quantitatively detect a disease biomarker. For a commercially available lateral flow test strip, the photoacoustic analysis improved the detection limit by two orders of magnitude compared to colorimetric measurements.

متن کامل

Flow Cytometric Detection of pAKT and FoxP3 in Jurkat T Cells Using TSA Plus Signal Amplification Technology

Tyramide signal amplification (TSA) is a reagent based method for amplification of weak signal in immunofluorescence, immunohistochemistry, in situ hybridization and similar image-based assays. Typically it provides 1-3 orders of magnitude improvement in the limit of detection, while reducing the exposure time and the amount of primary antibody or probe used in the assay. Here we demonstrate ap...

متن کامل

NAIL: Nucleic Acid detection using Isotachophoresis and Loop-mediated isothermal amplification.

Nucleic acid amplification tests are the gold standard for many infectious disease diagnoses due to high sensitivity and specificity, rapid operation, and low limits of detection. Despite the advantages of nucleic acid amplification tests, they currently offer limited point-of-care (POC) utility due to the need for complex instruments and laborious sample preparation. We report the development ...

متن کامل

Isotachophoresis with ionic spacer and two-stage separation for high sensitivity DNA hybridization assay.

We present an on-chip electrophoretic assay for rapid and high sensitivity nucleic acid (NA) detection. The assay uses isotachophoresis (ITP) to enhance NA hybridization and an ionic spacer molecule to subsequently separate reaction products. In the first stage, the probe and target focus and mix rapidly in free solution under ITP. The reaction mixture then enters a region containing a sieving ...

متن کامل

On-chip Isotachophoresis and Functionalized Hydrogel Capture for Sensitive Micro-rna Detection

We integrate on-chip isotachophoresis (ITP) and photopatterned functionalized hydrogels to perform rapid high-sensitivity detection of nucleic acids. We use ITP to enhance hybridization kinetics between target microRNAs and reporter oligos and remove excess reporters with a functionalized polyacrylamide capture gel. We achieve over 4000-fold background signal reduction, ~1 pM sensitivity, 4 ord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2015