Flow-sensitive MR imaging of ventriculoperitoneal shunts: in vitro findings, clinical applications, and pitfalls.

نویسنده

  • D G McLone
چکیده

To determine ventriculoperitoneal shunt patency during routine MR imaging of the head, 23 patients were studied with T1-weighted fast-field-echo scans. Without knowledge of the results of previous MR/CT studies or of the patients' clinical history, we reviewed the fast-field-echo studies and divided them according to those judged to have shunt flow (18) and those judged not to have flow (five). Fast-field-echo sequences showed high signal intensity, consistent with CSF flow and shunt patency in 17 medium-pressure systems and one high-pressure system. No signal was seen in five patients with high-pressure valve shunts. Combined clinical evaluation and MR/CT studies showed that three patients had probable shunt malfunction. One patient had true shunt malfunction; and although malfunction was thought to be present in two symptomatic patients, surgical revision showed the shunts to be patent. The possibility of temporary shunt obstruction is postulated to explain the clinical and MR findings in those two cases. The remaining two cases (9% of the patients) had no clinical evidence of shunt malfunction, and the MR findings probably reflected periodic CSF flow. One patient had an intracranial segment that was not connected and showed no flow on MR. No false-positive results (apparent flow in a nonfunctioning shunt) occurred. Using a standard medium-pressure shunt system, we constructed and imaged a phantom, which confirmed our clinical observations. T1-weighted fast-field-echo sequences may be useful in assessing patency of medium-pressure CSF shunt systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-Term Neuropsychological Sequelae in HIV-Seronegative Cryptococcal Meningoencephalitis Patients with and without Ventriculoperitoneal Shunts: A Cine MRI Study

BACKGROUND Hydrocephalus in cryptococcal meningoencephalitis is most commonly managed with a ventriculoperitoneal shunt. This study applied cine magnetic resonance imaging (MRI) to evaluate initial disease severity on long-term cerebrospinal fluid (CSF) flow dynamics and associated neuropsychological sequelae in cryptococcal meningoencephalitis patients with and without ventriculoperitoneal shu...

متن کامل

The Contribution of Common Surgically Implanted Hardware to Functional MR Imaging Artifacts.

BACKGROUND AND PURPOSE Blood oxygenation level-dependent MR imaging is increasingly used clinically to noninvasively assess cerebrovascular reactivity and/or language and motor function. However, many patients have metallic implants, which will induce susceptibility artifacts, rendering the functional information uninformative. Here, we calculate and interpret blood oxygenation level-dependent ...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1991