Consensus statement on inert gas washout measurement: at the threshold of clinical use.
نویسندگان
چکیده
I nert gas washout tests including single breath washout (SBW) and multiple breath washout (MBW) have been used for several decades across a wide age range spanning from early infancy to late adulthood. In the past, these lung function tests were typically applied in research settings, assessing lung volume and ventilation distribution in order to gain insight into presence, severity and progression of a multitude of diseases, such as chronic lung disease of infancy [1–4], cystic fibrosis [5–9], asthma [10–12] and chronic obstructive pulmonary disease [13–15]. Importantly, inert gas washout detects poor ventilation distribution in the presence of normal spirometry [16]. Until recently, inert gas washout testing was characterised by highly specific and at times incompletely validated hardware environments, customised software for data acquisition and analysis, and a general lack of consensus on criteria for processing and quality control of washouts across age groups. Thus, comparison and generalisability of study results from different laboratories testing patients with different diseases at different ages was extremely difficult. In this issue of the European Respiratory Journal, an international expert group of the European Respiratory Society (ERS) and American Thoracic Society (ATS) takes an important step forward towards overcoming some of the most demanding issues, by publishing a comprehensive statement on inert gas washout measurements [17].
منابع مشابه
ERS/ATS CONSENSUS STATEMENT Consensus statement for inert gas washout measurement using multiple- and single- breath tests
Inert gas washout tests, performed using the singleor multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. The...
متن کاملConsensus statement for inert gas washout measurement using multiple- and single- breath tests.
Inert gas washout tests, performed using the single- or multiple-breath washout technique, were first described over 60 years ago. As measures of ventilation distribution inhomogeneity, they offer complementary information to standard lung function tests, such as spirometry, as well as improved feasibility across wider age ranges and improved sensitivity in the detection of early lung damage. T...
متن کاملValidation of a photoacoustic gas analyser for the measurement of functional residual capacity using multiple-breath inert gas washout.
BACKGROUND The respiratory mass spectrometer is the current gold-standard technique for performing multiple-breath inert gas washout (MBW), but is expensive and lacks portability. A number of alternative techniques have recently been described. OBJECTIVES We aimed to validate, using an in vitro lung model, an open-circuit MBW system that utilises a portable photoacoustic gas analyser, with su...
متن کاملInert gas washout and HRCT in CF 0. MULTIPLE-BREATH INERT GAS WASHOUT AND SPIROMETRY VS. STRUCTURAL LUNG DISEASE IN CYSTIC FIBROSIS
AFFILIATIONS: 1. Queens Silvia Children’s Hospital, Göteborg, and Department of Pediatrics, The Sahlgrenska Academy at Göteborg, Sweden. 2. Erasmus Medical CenterSophia Children’s Hospital, Department of Pediatric Pulmonology and Allergology, Rotterdam, the Netherlands. 3. Meander Medical Center, Department of Radiology, Amersfoort, the Netherlands. 4. University Medical Center Utrecht, Departm...
متن کاملDouble tracer gas single-breath washout: reproducibility in healthy subjects and COPD.
The applicability and interpretation of inert tracer gas washout tests is hampered by the lack of feasible protocols and reproducibility data. We assessed feasibility, variability and reproducibility of a new easy to perform double tracer gas (DTG) single-breath washout (SBW) test and compared this with conventional nitrogen washouts. In 40 healthy nonsmokers and 20 patients with stable chronic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 41 3 شماره
صفحات -
تاریخ انتشار 2013