Measurement of hemoglobin A1c from filter papers for population-based studies.

نویسندگان

  • David A Egier
  • Judy L Keys
  • S Kim Hall
  • Matthew J McQueen
چکیده

BACKGROUND Stability and transport challenges make hemoglobin (Hb) A(1c) measurement from EDTA whole blood (WB) inconvenient and costly for large-scale population studies. This study investigated Hb A(1c) measurement from WB blotted on filter paper (FP) in a Level I National Glycohemoglobin Standardization Program (NGSP)-accredited laboratory. METHODS Three Bio-Rad Variant™ II HPLC instruments and WB and FP specimens were used. Precision, accuracy, linearity, and readable total area of the 6.5-min (β-thalassemia method) Variant II HbA(2)/HbA(1c) Dual Program were assessed. Hb A(1c) stability was measured using in-house FP QC samples. The INTERHEART (a study of the effect of potentially modifiable risk factors associated with myocardial infarction in 52 countries) and CURE (Clopidogrel in Unstable Angina to Prevent Recurrent Events) studies provided chromatographs for morphometric analyses and interoperator variability experiments. Statistical analyses were performed to assess long-term sample stability, WB vs FP agreement, and significance of Hb A(1c) peak integration. RESULTS Intra- and interassay CVs were ≤2.00%. Total area counts between 0.8 and 5.5 × 10(6) μV/s produced accurate Hb A(1c) results. The regression equation for agreement between WB(x) and FP(y) was as follows: y = 0.933x + 0.4 (n = 85). FP QC samples stored at -70 °C and tested over approximately 3 years yielded CVs of 1.72%-2.73% and regression equations with slopes of -1.08 × 10(-4) to 7.81 × 10(-4). The CURE study, with better preanalytical preparation, achieved a 97% reportable rate, and the reportable rate of the INTERHEART study was 85%. CONCLUSIONS The FP collection method described provided accurate, robust, and reproducible measurement of Hb A(1c) using the Bio-Rad Variant II HPLC autoanalyzer when FP specimens were prepared according to standardized protocols, and analyses were performed in an NGSP-certified laboratory, supporting the use of FP collection cards in large multinational studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Iron Deficiency Anemia on Hemoglobin A1C Levels in Diabetic Individuals with Controlled Plasma Glucose Level

Introduction: Hemoglobin A1C (HbA1c) reflects patient’s glycemic status over the previous 3 months. Previous studies have reported that iron deficiency may elevate A1C concentrations, independent of glycemia. This study is aimed to analyze the effect of iron deficiency anemia on HbA1c levels in diabetic population having plasma glucose levels in control. Methods: Totally, 120 diabetic, iron-def...

متن کامل

Predictors of Pre-diabetes Hemoglobin A1C Test in Overweight Obese and Overweight Employees Based on Protection Motivation Model

Background objective: This research paper aimed at to study the factors in relevance to the performance of screening behavior in per diabetes based on the stimulus model of preserve from the overweight and obese personnel of Karaj education administration. Materials and methods: the research method of the study is descriptive-analytical one and the statistical community of survey, are including...

متن کامل

The Optimal Cutoff Value of Glycated Hemoglobin for Detection of Diabetic Retinopathy

With standardization of measurement of glycated hemoglobin (A1C), the International Expert Committee Report in 2009 and the American Diabetes Association in 2010 recommended incorporating A1C ≥6.5% into the previous diagnostic criteria using fasting plasma glucose and/or 2-hour plasma glucose. Whereas the association of A1C with cardiovascular diseases and other diabetic microvascular complicat...

متن کامل

Hemoglobin A1c measurement for the diagnosis of Type 2 diabetes in children

Laboratory measurements of hemoglobin A1c above 6.5% were approved as an additional diagnostic criteria for diabetes mellitus by the American Diabetes Association in 2010. Several recent pediatric studies have cast HbA1c measurement in children in an unfavorable light in the pediatric population, by comparing HbA1c measurements to results on oral glucose tolerance test (OGTT) or fasting plasma ...

متن کامل

Comparability of hemoglobin A1c level measured in capillary versus venous blood sample applying two point-of-care instruments

BACKGROUND The present study is designed to evaluate the validity of the measurement of capillary blood hemoglobin A1c levels in comparison with venous blood hemoglobin A1c. METHODS The data of this cross-sectional study are collected from a sample of 45 Iranian diabetic patients referred to one particular laboratory for the assessment of HbA1c level during a period from April to December 201...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2011