The Orbit Galaxy XTRASOFT Coils: A Multicenter Study of Coil Safety and Efficacy in Both Ruptured and Unruptured Cerebral Aneurysms.

نویسندگان

  • Ahmad Khaldi
  • Kyle M Fargen
  • Ben Waldau
  • Adnan H Siddiqui
  • Brian L Hoh
  • William Mack
  • Jeffrey Carpenter
  • Erol Veznedaroglu
  • J Mocco
چکیده

Increase packing density with the use of softer three-dimensional (3D) coils has been indicated in reducing aneurysm recurrence. We are reporting a multicenter initial experience of using the Orbit Galaxy XTRASOFT which is a stretch-resistant, softer 3D coil in both ruptured and unruptured aneurysms. A total of 57 consecutive patients from five high-volume neurointerventional centers were reported where at least one Galaxy XTRASOFT coil was used during a procedure. There were 25 patients with ruptured aneurysm and 32 with elective coiling. The overall complication rate was 3.5%, one patient with nonoperative retroperitoneal hematoma and one patient with intraoperative rupture but with no neurological deficit. The occlusion rate of 90% or greater was achieved in 86% of the cases. The discharge modified Rankin score of 0 or 1 was achieved in 100% of the elective coiling and 65% in the ruptured cases. Early experience with Galaxy XTRASOFT coils for both ruptured and unruptured aneurysms appears to be safe with good aneurysm obliteration and low complication rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endovascular Embolization of Intracranial Aneurysms Using Bare Platinum Axium™ Detachable Coils: Immediate and Short-Term Follow-up Results from a Multicenter Registry

PURPOSE Axium™ coils were developed to improve the durability of coil-embolized cerebral aneurysms by increasing packing density. The purpose of this prospective multicenter registry was to evaluate the safety and durability of Axium™ coils. MATERIALS AND METHODS One hundred twenty-six patients with 135 aneurysms of ≤ 15 mm in size underwent coil embolization using bare platinum coils, with A...

متن کامل

Cerebral aneurysm perforations complicating therapy with Guglielmi detachable coils: a meta-analysis.

BACKGROUND AND PURPOSE The risk of intraprocedural aneurysm perforation in patients with previously ruptured aneurysms tends to be higher than that of patients with previously unruptured aneurysms, but a statistically significant difference has not been shown. Our purpose was to define the rates of occurrence and of morbidity and mortality associated with aneurysmal perforation associated with ...

متن کامل

The eJournal of the European Society of Minimally Invasive Neurological Therapy

INTRODUCTION: Bare platinum coils have demonstrated safety and efficacy in the treatment of intracranial aneurysms; however, a persistent and important limitation occurs in the form of delayed recanalisation. The authors report their multiple-hospital, single-practice experience with the use of first and second-generation hydrogel coils for the treatment of ruptured and unruptured cerebral aneu...

متن کامل

Periprocedural complications associated with endovascular embolisation of intracranial ruptured aneurysms with matrix coils.

INTRODUCTION Matrix is a type of bioactive coil expected to produce healing of cerebral aneurysms. We reviewed periprocedural complications associated with endovascular embolisation of ruptured intracranial aneurysms with matrix coils and evaluated the effects of matrix coils. METHODS From October 2003 to September 2005, a total of 102 patients with 102 ruptured aneurysms and ten unruptured a...

متن کامل

Cerecyte coil trial: procedural safety and clinical outcomes in patients with ruptured and unruptured intracranial aneurysms.

BACKGROUND AND PURPOSE This study arose from a need to systematically evaluate the clinical and angiographic outcomes of intracranial aneurysms treated with modified coils. We report the procedural safety and clinical outcomes in a prospective randomized controlled trial of endovascular coiling for ruptured and unruptured intracranial aneurysms, comparing polymer-loaded Cerecyte coils with bare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional neurology

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2012