Inspiratory Capacity as an Indirect Measure of Immediate Effects of Positive Expiratory Pressure and CPAP Breathing on Functional Residual Capacity in Healthy Subjects.
نویسندگان
چکیده
BACKGROUND Positive expiratory pressure (PEP) and CPAP are used to enhance breathing parameters such as functional residual capacity (FRC) in patients. Studies comparing effects of PEP and CPAP on FRC are few and variable. One reason for this may be that sophisticated equipment, not suitable in the clinical setting, is required. Because total lung capacity (TLC) consists of inspiratory capacity (IC) and FRC, a change in IC should result in a corresponding change in FRC given constant TLC. We aimed to evaluate the effects of different PEP and CPAP devices on IC as an indirect measure of induced changes in FRC from these devices in healthy subjects. METHODS Twenty healthy subjects breathed with 2 PEP devices, a PEP mask (flow resistor) and a PEP bottle (threshold resistor), and 2 CPAP devices, a flow resistor and a threshold resistor, in a randomized order. The measurement sequence consisted of 30 breaths with an IC measurement performed before and immediately after the 30th breath while the subjects were still connected to the breathing device. Perceived exertion of the 30 breaths was measured with the Borg category ratio 10 scale. RESULTS Three of the 4 breathing devices, the PEP mask and the 2 CPAP devices, significantly decreased IC (P < .001). Median perceived exertion was quite low for all 4 breathing devices, but the difference in perceived exertion among the different breathing devices was large. CONCLUSIONS Provided that TLC is constant, we found that measurements of changes in IC could be used as an indirect measure of changes in FRC in healthy subjects. All investigated breathing devices except the PEP bottle decreased IC, as an indirect measure of increased FRC.
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملEffect of positive expiratory pressure on breathing pattern in healthy subjects.
The purpose of this study was to register breathing patterns, in healthy subjects, during breathing with a positive expiratory pressure. Integrated electromyographic (IEMG) activity of the following muscles was assessed: scalene muscle, parasternal muscle and abdominal muscles, using surface electrodes. Inspiration time, expiration time, total breathing cycle time, tidal volume and breathing fr...
متن کاملPneumatic performance of the Boussignac CPAP system in healthy humans.
BACKGROUND The Boussignac continuous positive airway pressure (CPAP) device effectively treats acute pulmonary edema, but data on airway pressure with the Boussignac CPAP system are sparse. OBJECTIVE To evaluate the Boussignac CPAP system's ability to maintain stable inspiratory and expiratory pressure levels, and to evaluate perceived exertion during breathing with the Boussignac CPAP system...
متن کاملContinuous positive airway pressure effect on functional residual capacity, vital capacity and its subdivisions.
Thirty-four otherwise healthy patients having to undergo elective upper abdominal surgery were randomly assigned to two equal groups. In the treatment group, constant positive airway pressure (CPAP) with an expiratory pressure of 12 cm H2O was applied at one hour following extubation, and at daily intervals for the first five days following surgery for a continuous period of three hours. The co...
متن کاملChest physiotherapy after coronary artery bypass graft surgery--a comparison of three different deep breathing techniques.
The effectiveness of three deep breathing techniques was evaluated in 98 male patients after coronary artery bypass graft surgery in a randomized trial. The techniques examined were deep breathing with a blow bottle-device, an inspiratory resistance-positive expiratory pressure mask (IR-PEP) and performed with no mechanical device. Pulmonary function and roentgenological changes were evaluated....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 60 10 شماره
صفحات -
تاریخ انتشار 2015