Development of Maintenance Strategy to Improve Performance of Natural Draft Cooling Tower

نویسندگان

  • Neetesh Singh
  • Alok Singh
چکیده

Cooling tower is an important part of power plant. The efficiency of power plant is directly depends on the effectiveness of cooling tower. In cooling tower scheduled maintenance and shutdown maintenance is a problem which affects its effectiveness and performance of cooling tower. In cooling tower shutdown maintenance required in every 2 to 3 year periods at this period the whole plant will be shutdown, and require 28 to 35 days maintenance so that cooling tower will be in its best working condition. In every cooling tower manufacturer provide the scheduled maintenance check list so that the worker will perform their maintenance as per given instruction. In present work optimization of shutdown maintenance strategy is done so that the time elapsed in maintenance will reduce and the requirement of man power will be reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comprehensive Approach to an Optimum Design and Simulation Model of a Mechanical Draft Wet Cooling Tower

The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....

متن کامل

Development of Maintenance Strategy to Improve Performance of Induce Draft Wet Cooling Tower

Throughout the years, the importance of the maintenance management system and their functions has grown rapidly. Cooling towers are used in many process applications in the various industries. Reliability of these towers is crucial. In many cases, redundant towers are installed to ensure a process will not have to be stopped due to a cooling tower failure. The most prevalent cause of cooling to...

متن کامل

بهینه سازی تک معیاره و چند معیاره برج خنک کن خشک هلر در نیروگاه‌های سیکل ترکیبی با استفاده از الگوریتم ژنتیک

In this paper the effect of site conditions, which are Altitude, Temperature and Relative Humidity and also Heat Dissipation Capacity are investigated on the optimized design of natural draft dry cooling towers with specific kind of heat exchangers, known as Forgo T60 type. A genetic algorithm program has been developed for optimized design of these cooling towers. Objective function includes b...

متن کامل

Feasibility Study of the Thermal Performance Improvement of Natural Draft Dry Cooling Towers Due to Flue Gas Injection

In steam power plants, any improvement in the cooling towers thermal performance will cause the condenser's temperature to decrease; which in turn enhances the power plant's efficiency. Due to water shortage, many power plants all around the world rely on natural draft dry cooling towers (Heller type). In these cooling towers, condenser's exit hot water is pumped to vertical or horizontal finne...

متن کامل

Energy and Second Law of Thermodynamics Analysis of Shower Cooling Tower with Variation in Inlet Air Temperature

A shower cooling tower (SCT) operates without fill because of salt decomposition on the fill that leads to deterioration of conventional cooling tower performance. This study presents a two-dimensional mathematical model for energy and exergy analysis of multi-diameter droplets and air interaction along with the height of the forced draft SCT, to predict the exit condition of water droplet for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014