Quantitative evaluation of phonomicrosurgical manipulations using a magnetic motion tracking system.

نویسندگان

  • Ting Chen
  • Ketan Surender
  • Andrew C Vamos
  • Seth H Dailey
  • Jack J Jiang
چکیده

OBJECTIVES/HYPOTHESIS To present and evaluate the magnetic-based phonomicrosurgery instrument tracking system, a novel and objective method of acquiring instrument position data during simulated phonomicrosurgery. The position data can be used to compute quantitative motion metrics. This system was used to objectively evaluate the motion performance of novice and expert surgeons during phonomicrosurgical simulations and determine the differences between these groups. STUDY DESIGN Prospective cohort study. METHODS A magnetic-based phonomicrosurgery instrument tracking system was developed, including a workbench, independent task, motion metrics, and computer program. Based on this system, three experts' and six novices' motion data were collected and analyzed. RESULTS Experts demonstrated significantly better motion smoothness along the y-axis for the dominant hand. For the nondominant hand, experts demonstrated better motion smoothness along all three axes, shorter path length, and better depth perception (P < .05). Experts also demonstrated higher quality of operation (P < .001). No significant difference in time was noted (P = .671). CONCLUSIONS Parameters derived from magnetic-based motion tracking were able to differentiate between expert and novice surgeons. These parameters have the potential to be used in phonomicrosurgical training as feedback to enhance the training process.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

CUSUM analysis of learning curves for the head-mounted microscope in phonomicrosurgery.

OBJECTIVES/HYPOTHESIS To observe the learning curve of the head-mounted microscope in a phonomicrosurgery simulator using cumulative summation (CUSUM) analysis, which incorporates a magnetic phonomicrosurgery instrument tracking system (MPTS). STUDY DESIGN Retrospective case series. METHODS Eight subjects (6 medical students and 2 surgeons inexperienced in phonomicrosurgery) operated on pho...

متن کامل

VISCOUS NUTATION DAMPER, MODELING AND ANALYSIS

In some aerospace vehicles, the tracking sensors which act in a tracking loop as stabilizer are mounted on a two degree of freedom gyro. The gyro must align its rotor axis with the line of sight in order to remove tracking errors. The tracking precision and sensitivity are functions of the gyros performance. One of the main factors in reducing the precision and producing instabilities is nutati...

متن کامل

Tracking and Shape Control of a Micro-cantilever using Electrostatic Actuation

In this paper the problems of state estimation, tracking control and shape control in a micro-cantilever beam with nonlinear electrostatic actuation are investigated. The system’s partial differential equation of motion is converted into a set of ordinary differential equations by projection method. Observabillity of the system is proven and a state estimation system is designed using extended ...

متن کامل

مدل‌سازی دینامیکی و کنترل ربات فضایی متصل به تتر

In present study, dynamic modeling and control of a tethered space robot system in trajectory tracking of its end effector is investigated. Considering variation of the tether length in the model, dynamics of the system is modeled using Lagrange&rsquo;s method. Librational motion of the tether is controlled by adjusting the tether length similar to conventional manipulators,control of the robot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Laryngoscope

دوره 124 9  شماره 

صفحات  -

تاریخ انتشار 2014