The prevalence of self-monitoring of blood glucose and costs of glucometer strips in a nationwide cohort.
نویسندگان
چکیده
OBJECTIVE This study used nationwide data to determine the prevalence of self-monitoring of blood glucose (SMBG) among all non-institutionalized persons living in Norway and to estimate the prevalence of SMBG among diabetes patients, the frequency and cost of SMBG, and the use of different glucometers. METHODS This retrospective, descriptive study is based on data of sales of glucometer strips to non-institutionalized persons in Norway in 2008. The data included gender, age group, month of purchase, sales place, type of strips, number of packages dispensed, and cost of strips. Additionally, statistics on sales of insulin and oral antidiabetes medications were obtained from the Norwegian Prescription Database. RESULTS A total of 96,999 persons purchased strips, a prevalence of 2%. Approximately 70% of diabetes patients practiced SMBG. An average patient used 1.7 strips per day, and younger patients purchased more strips than older patients. Fewer than 50% of patients performed glucose measurements daily. One percent of patients used more than 10 strips daily and was accountable for 8% of total costs. Most patients used only one type of strips, but the number of strips purchased increased with the number of different strips. The average annual cost of strips was 446 euro per person. CONCLUSIONS Two percent of all non-institutionalized inhabitants and an estimated 70% of patients using diabetes medication purchased SMBG strips. A small percentage of the patients incurred a substantial proportion of the costs. This, along with the fact that over half of the patients monitor less than once per day, calls for tighter follow-up of diabetes patients.
منابع مشابه
مقایسه میزان همخوانی یافتههای سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد
Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...
متن کاملبررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد
Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...
متن کاملA Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...
متن کاملبررسی ارزش گلوکومتری در تشخیص هیپوگلیسمی نوزادان
Background and purpose: Hypoglycemia is an important problem in newborns which requires early diagnosis and treatment. Laboratory testing of blood glucose level and glucometer readings are used to detect hypoglycemia but sometimes the results are given late. This study aimed at evaluating the accuracy of glucometer in detection of hypoglycemia in newborns at neonate intensive care unit (NICU), ...
متن کاملQuality assessment of patients’ self-monitoring of blood glucose in community pharmacies
OBJECTIVE To evaluate diabetes patients' self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. METHODS The results of patient blood glucose measurements were comp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diabetes technology & therapeutics
دوره 12 9 شماره
صفحات -
تاریخ انتشار 2010