Accuracy Improvement in Camera Calibration
نویسندگان
چکیده
Camera calibration is a necessary and critical step in 3D object analysis. The accuracy of calibration results will affect the object’s position in world coordinates, especially for 3D object tracking. In this paper, we present a new camera calibration approach, and discuss its accuracy. We use 3D marks instead of 2D marks for calibration. Our experimental results show that our approach has the potential to improve the calibration accuracy.
منابع مشابه
Measuring and improving the accuracy of ARDev using a square grid
Augmented reality (AR) systems superimpose 3D virtual objects on top of a real scene. Most applications require the AR system to maintain an accurate registration between the virtual objects and the real scene. Many AR systems use parameters obtained from the camera calibration to set up a virtual camera that models the real camera. Thus, inaccuracy in camera calibration can adversely affect th...
متن کاملImprovement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method
Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...
متن کاملRobust Line-based Calibration of Lens Distortion from a Single View
Line-based camera calibration methods estimate the radial lens distortion from a single view. They use only the constraint, that straight lines in the 3D world must project to straight lines in the image plane, if the distortion is compensated. Therefore neither calibration pattern nor information about other camera parameters are necessary. Former approaches are impaired by real curved lines i...
متن کاملRange Camera Self-Calibration Based on Integrated Bundle Adjustment via Joint Setup with a 2D Digital Camera
Time-of-flight cameras, based on photonic mixer device (PMD) technology, are capable of measuring distances to objects at high frame rates, however, the measured ranges and the intensity data contain systematic errors that need to be corrected. In this paper, a new integrated range camera self-calibration method via joint setup with a digital (RGB) camera is presented. This method can simultane...
متن کاملLaser-Video Scanner Calibration without the use of a frame store
Abstract We present a new calibration method for a structured light surface scanner. The new method uses a model-based calibration, accounting for laser stripe and translation stage alignment and the internal and external camera parameters. The inclusion of non-linear radial distortion in the camera model gives an improvement in the calibration accuracy over a linear model. The method has been ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2003