Protection against cold in prehospital care-thermal insulation properties of blankets and rescue bags in different wind conditions.

نویسندگان

  • Otto Henriksson
  • J Peter Lundgren
  • Kalev Kuklane
  • Ingvar Holmér
  • Ulf Bjornstig
چکیده

INTRODUCTION In a cold, wet, or windy environment, cold exposure can be considerable for an injured or ill person. The subsequent autonomous stress response initially will increase circulatory and respiratory demands, and as body core temperature declines, the patient's condition might deteriorate. Therefore, the application of adequate insulation to reduce cold exposure and prevent body core cooling is an important part of prehospital primary care, but recommendations for what should be used in the field mostly depend on tradition and experience, not on scientific evidence. OBJECTIVE The objective of this study was to evaluate the thermal insulation properties in different wind conditions of 12 different blankets and rescue bags commonly used by prehospital rescue and ambulance services. METHODS The thermal manikin and the selected insulation ensembles were setup inside a climatic chamber in accordance to the modified European Standard for assessing requirements of sleeping bags. Fans were adjusted to provide low (< 0.5 m/s), moderate (2-3 m/s) and high (8-9 m/s) wind conditions. During steady state thermal transfer, the total resultant insulation value, Itr (m2 C/Wclo; where C = degrees Celcius, and W = watts), was calculated from ambient air temperature (C), manikin surface temperature (C), and heat flux (W/m2). RESULTS In the low wind condition, thermal insulation of the evaluated ensembles correlated to thickness of the ensembles, ranging from 2.0 to 6.0 clo (1 clo = 0.155 m2 C/W), except for the reflective metallic foil blankets that had higher values than expected. In moderate and high wind conditions, thermal insulation was best preserved for ensembles that were windproof and resistant to the compressive effect of the wind, with insulation reductions down to about 60-80% of the original insulation capacity, whereas wind permeable and/or lighter materials were reduced down to about 30-50% of original insulation capacity. CONCLUSIONS The evaluated insulation ensembles might all be used for prehospital protection against cold, either as single blankets or in multiple layer combinations, depending on ambient temperatures. However, with extended outdoor, on-scene durations, such as during prolonged extrications or in multiple casualty situations, the results of this study emphasize the importance of using a windproof and compression resistant outer ensemble to maintain adequate insulation capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating cold, wind, and moisture protection of different coverings for prehospital maritime transportation-a thermal manikin and human study.

INTRODUCTION Prehospital maritime transportation in northern areas sets high demands on hypothermia prevention. To prevent body cooling and hypothermia of seriously-ill or injured casualties during transportation, casualty coverings must provide adequate thermal insulation and protection against cold, wind, moisture, and water splashes. OBJECTIVE The aim of this study was to determine the the...

متن کامل

Protection against cold in prehospital care: evaporative heat loss reduction by wet clothing removal or the addition of a vapor barrier--a thermal manikin study.

INTRODUCTION In the prehospital care of a cold and wet person, early application of adequate insulation is of utmost importance to reduce cold stress, limit body core cooling, and prevent deterioration of the patient's condition. Most prehospital guidelines on protection against cold recommend the removal of wet clothing prior to insulation, and some also recommend the use of a waterproof vapor...

متن کامل

Efficacy of rescue blanket versus conventional blanket in terms of preventing accidental hypothermia during patient transfer by emergency medical service: a randomized clinical trial

Objective: This study aimed to compare the efficacy of rescue blankets with conventional blankets in terms of preventing hypothermia in the pre-hospital setting. Methods: In this randomized clinical trial, patients older than 18 years old with Cold Discomfort Scale (CDS) > 2, and those who were transferred to the emergency department (ED) by emergency medical service entered the study. Patients...

متن کامل

Bubblewrap for hypothermia prevention – the ultimate solution or yet another fancy gadget?

Introduction The cold climate in Norway demands a persistent prehospital effort to prevent hypothermia in the seriously ill or injured patient. The current trend among HEMS (Helicopter Emergency Medical Services) in Norway is to wrap the patient in bubblewrap during the prehospital phase. To our knowledge, no risk assessment of this procedure has been done and its efficiency in preventing hypot...

متن کامل

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prehospital and disaster medicine

دوره 24 5  شماره 

صفحات  -

تاریخ انتشار 2009