Jet or intensive care unit ventilator during simulated percutaneous transtracheal ventilation: a lung model study.
نویسندگان
چکیده
BACKGROUND Percutaneous transtracheal ventilation (PTV) via a jet ventilator (PTJV) is considered a rescue technique in difficult airway management. However, whether a conventional ventilator can generate adequate ventilation via PTV is not known. Our goal was to evaluate the tidal volume (V(T)) generated by a conventional ventilator during simulated PTV compared with PTJV in a lung model. METHODS A lung model simulating an adult lung was used. A catheter was inserted through the artificial trachea and connected to either a jet ventilator or a conventional ventilator. The direction of catheter insertion was perpendicular to the trachea, pointing towards the lung and away from the lung. The jet ventilator was operated at 344.7 kPa. The conventional ventilator was operated in the pressure mode at peak inspiratory pressures of 40-90 cm H(2)O. RESULTS The jet ventilator generated larger V(T) [817 (336) ml] when the catheter was pointing towards the lung than when pointing away from the lung or perpendicular to the trachea [121 (41) and 69 (24) ml, respectively, P<0.01]. With the conventional ventilator, changes in V(T) at different direction of catheter insertion were much less [222 (81) ml catheter pointing towards the lung, 229 (121) ml perpendicular to the trachea, and 187 (97) ml away from the lung]. CONCLUSIONS Our result demonstrated that PTJV was effective only when the catheter was pointing towards the lung and requires high operating pressure. A conventional ventilator can generate reasonable minute ventilation through the transtracheal catheter less dependent on directions of catheter insertion and should be considered during emergent PTV.
منابع مشابه
Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery
Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...
متن کاملTracheal gas insufflation and related techniques to introduce gas flow into the trachea.
Over the past 50 years, a variety of techniques have been developed that have in common the insufflation of gas into the central airway to facilitate carbon dioxide (CO2) clearance. These include continuous insufflation of oxygen, transtracheal jet ventilation, high frequency jet ventilation, transtracheal oxygen administration, intratracheal pulmonary ventilation, and tracheal gas insufflation...
متن کاملPercutaneous Transtracheal Jet Ventilation with Various Upper Airway Obstruction
A "cannot-ventilate, cannot-intubate" situation is critical. In difficult airway management, transtracheal jet ventilation (TTJV) has been recommended as an invasive procedure, but specialized equipment is required. However, the influence of upper airway resistance (UAR) during TTJV has not been clarified. The aim of this study was to compare TTJV using a manual jet ventilator (MJV) and the oxy...
متن کاملAssociation between admission hypomagnesemia mortality or mortality of critically ill patients in intensive care unit
Background: Up to now there is no study evaluating correlation between serum magnesium and morbidity or mortality in patients admitted in intensive care unit. The aim of this study is to determine the prevalence of hypomagnesemia in critically ill patients and to evaluate its association with organ dysfunction, hospitalization period and mortality. Methods: We conducted a retrospective trial ...
متن کاملEfficacy of ventilation through a customized novel cuffed airway exchange catheter: a tracheal/lung model study.
Editor—Airway exchange catheters (AECs) are commonly used in difficult airways management as a guide for re-intubation or ventilation when attached to a jet ventilator. However, barotrauma resulting in pneumothorax has been a major concern when using jet ventilation with AECs. – 4 The cause of these complications is often the excessive driving pressure with jet ventilation (15–50 psi) or airway...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 110 3 شماره
صفحات -
تاریخ انتشار 2013