Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use.
نویسندگان
چکیده
BACKGROUND The sleep apnoea/hypopnoea syndrome (SAHS) is common and treatment with continuous positive airway pressure (CPAP) is effective. However, not all patients can cope with the demands of using mask positive pressure. Compliance can be improved with an intensive educational programme and patient support, but this is not practical in most centres given the large numbers of patients coming forward for treatment. Several studies have evaluated correlations between various parameters at diagnosis in order to anticipate patients' behaviour and to avoid the social and health implications of undertreated SAHS. We have evaluated the use of additional data derived during a 2 week home CPAP trial to identify factors associated with longer term use of CPAP and compliance. METHODS Following a diagnostic study, 209 patients were offered a CPAP machine for a 2 week home trial. After completing the trial, patients were reassessed and scored their overall satisfaction with CPAP treatment on a five point scale ranging from "much worse" to "much better" and an Epworth score relating to the loan period. Machine run time was recorded from the integral clock. These data were added to those available at diagnosis to construct models indicative of continuing CPAP and average nightly use at 1 year. RESULTS 209 patients were offered the 2 week loan at least a year before June 1999 (90.9% men, mean (SD) age 51.0 (10.6) years, body mass index (BMI) 34.6 (7.7) kg/m(2), Epworth score 15 (IQR 11-18), apnoea/hypopnoea index (AHI) 38.1 (22.9) events/h). 153 patients (73.2%) opted to continue CPAP and 56 declined. One year later data were available for 187 patients; 128 (68.5% on an intention to treat analysis) continued to use the machine with a mean use of 5.0 (2.4) hours/night. A logistic regression model indicated that mean CPAP use during the loan period and the overall satisfaction score accurately defined continuing CPAP and "satisfactory" CPAP use at 1 year. For patients with low machine use and no symptomatic improvement during the loan period, the addition of baseline AHI, baseline Epworth score, and the Epworth score at the end of the loan to the equation identifying factors associated with "satisfactory" CPAP use (mean >2 hours/night) improved the value of the model. CONCLUSION Data derived from a 2 week CPAP trial are useful in identifying patients who will comply with CPAP treatment to 1 year. It can be used to identify patients with significant symptomatic disease who will struggle with CPAP and may benefit from additional education and support. High mean hourly use and a high degree of overall satisfaction during the loan period identified patients likely to use CPAP and be compliant with it at 1 year.
منابع مشابه
Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome.
We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL)...
متن کاملSplit-night versus full-night studies for sleep apnoea/hypopnoea syndrome.
Investigation and treatment of sleep apnoea/hypopnoea syndrome (SAHS) is placing increasing demands on healthcare resources. This workload may be reduced by using split-night studies instead of the standard full-nights of diagnostic polysomnography and continuous positive airway pressure (CPAP) titration. Split-night studies involve polysomnography in the first half of the night followed, if th...
متن کاملRequired levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnoea.
The improvement in the severity of obstructive sleep-related breathing disorders during nasal continuous positive airway pressure (NCPAP) therapy can account for the decrease in the required NCPAP level with time. The aim of this study was to prospectively quantify the changes in the required NCPAP level over time of use in sleep apnoea-hypopnoea syndrome (SAHS). Forty sleep apnoea-hypopnoea pa...
متن کاملCase reports Transtracheal air in the treatment of obstructive sleep apnoea hypopnoea syndrome
A 49 year old woman with typical obstructive sleep apnoea hypopnoea syndrome underwent an unsuccessful trial with continuous positive airway pressure (CPAP) followed by uvulopalatopharyngoplasty with septorhinoplasty, treatment with protriptyline, and a second CPAP trial that was abandoned. Transtracheal air was then given and normalised sleep and breathing at a flow rate of 5 l/min. A sustaine...
متن کاملTumour necrosis factor-α/interleukin-10 ratio in patients with obstructive sleep apnoea hypopnoea syndrome.
OBJECTIVE To explore the significance of the tumour necrosis factor-α/interleukin-10 ratio and the effect of continuous positive airway pressure in patients with different degrees of obstructive sleep apnoea hypopnoea syndrome severity. METHOD This study comprised 135 patients with obstructive sleep apnoea hypopnoea syndrome and 94 control subjects. RESULTS Tumour necrosis factor-α and tumo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 56 9 شماره
صفحات -
تاریخ انتشار 2001