The use of water structure breakers, urea and guanidium chloride, new mobile phase modifiers in reversed-phase partition high-performance liquid chromatography.

نویسندگان

  • T Takahashi
  • H Hoshino
  • T Yotsuyanagi
چکیده

Organic solvent-free mobile-phase systems in ion-pair reversed-phase partition high-performance liquid chromatography (IPRP-HPLC) are demonstrated; using urea at 3.0-7.0 molal (mol kg-1) as a modifier in a mobile phase on an octadecylsilanized silica column, four nitrophenolates and metal 4-(2-pyridilazo)resorcinol (PAR) chelates (in PAR chelates system an aqueous mobile phase with 15 wt% methanol was used) were separated rapidly within 6 min at no sacrifice to the separation efficiency. On the addition of urea in the mobile phase, reduced retention times of nitrophenolates and naphthalenesulfonates and also diminution of the height equivalent to a theoretical plate were observed. The addition of urea and guanidium chloride (GuCl) in the mobile phase gave rise to a decrease in the mobile phase volume; in turn, this meant an increased volume of the stationary phase. As the concentration of urea and GuCl in the mobile phase increased, the volume of the mobile phase in the column decreased within about 70% and 40% at 7.0 molal of urea and GuCl, respectively. A decrease in the mobile phase volume suggests an increase in the extent of solvation of the bonded hydrocarbon chain of the stationary phase. The possible explanations for the LC behavior with the urea and GuCl are turned into reduction of hydrophobic interaction in LC processes, solute partitioning and entangling of alkyl chain brushes, with the addition of urea. The water structure breakers, urea and GuCl, most likely affect the solvation states of both solute molecules and the hydrocarboneous stationary phase by changing the nature of the water solvent, which provides a new technique for fine tuning of the LC resolution of the analytes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC

A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...

متن کامل

A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...

متن کامل

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2001