Evaluation of Gen-Probe APTIMA-based Neisseria gonorrhoeae and Chlamydia trachomatis confirmatory testing in a metropolitan setting of high disease prevalence.

نویسندگان

  • Erik Munson
  • Vivian Boyd
  • Jolanta Czarnecka
  • Judy Griep
  • Brian Lund
  • Nancy Schaal
  • Jeanne E Hryciuk
چکیده

Prompted by reports challenging the validity of the low-positive Neisseria gonorrhoeae and Chlamydia trachomatis results generated by the APTIMA Combo 2 assay (Gen-Probe, Incorporated) and by a Centers for Disease Control and Prevention recommendation to confirm N. gonorrhoeae- or C. trachomatis-positive screens by using an alternative amplification target, we report on a comparison of this means of confirmation with an in-house algorithm of repeat testing. Primary clinical specimens yielding N. gonorrhoeae- or C. trachomatis-specific luminescent values between 100,000 and 1,000,000 were repeat tested in duplicate. A subset of specimens was forwarded for confirmatory assays (Gen-Probe) individualized for alternative N. gonorrhoeae or C. trachomatis targets. An 18-month audit revealed that 230 of 29,977 C. trachomatis screens (0.8%) and 41 of 29,064 N. gonorrhoeae assays (0.1%) yielded low-positive data. When a subset of 40 low-positive N. gonorrhoeae screens was repeat tested, 20 (50.0%) remained positive; 22 (55.0%) of the screens remained positive following performance of the confirmatory assay. In contrast, repeat testing of 153 low-positive C. trachomatis screens yielded a positive result for fewer specimens (n = 97; 63.4%) than when commercial confirmatory testing was used (n = 124; 81.0%). However, confirmation of the results for additional C. trachomatis screens by use of an alternative target did not translate into significant differences in the calculated overall C. trachomatis-positive screen rates (7.39% by repeat testing versus 7.52% by the confirmatory assay; P = 0.53). Furthermore, use of the confirmatory assay raised the positive predictive value only 1.8% over that of repeat testing. Molecular confirmatory testing did not significantly enhance the reliability of C. trachomatis- or N. gonorrhoeae-specific nucleic acid amplification testing in this metropolitan setting compared to the reliability of repeat testing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abilities of APTIMA, AMPLICOR, and ProbeTec assays to detect Chlamydia trachomatis and Neisseria gonorrhoeae in PreservCyt ThinPrep Liquid-based Pap samples.

Infections with Chlamydia trachomatis and Neisseria gonorrhoeae are often asymptomatic. Liquid-based Pap (L-Pap) screening may provide samples for testing by commercial assays. Women attending a health clinic or a street youth clinic had a PreservCyt ThinPrep sample and a cervical swab (CS) collected. The L-Pap sample was tested for cytopathology; then 1 ml was transferred to an L-Pap specimen ...

متن کامل

Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

The Gen-Probe APTIMA Combo 2 (AC2) is a Food and Drug Administration-cleared nucleic acid amplification test (NAAT) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae from urine and urogenital swab specimens. The Centers for Disease Control and Prevention have recommended confirmation of positive NAAT results in low-prevalence populations. APTIMA CT (ACT) and APTIMA GC (AGC) a...

متن کامل

Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.

A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...

متن کامل

Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, ...

متن کامل

Positive predictive value of Gen-Probe APTIMA Combo 2 testing for Neisseria gonorrhoeae in a population of women with low prevalence of N. gonorrhoeae infection.

We collected specimens from women who tested positive for Neisseria gonorrhoeae using the Gen-Probe APTIMA Combo 2 (AC2), and we performed confirmatory tests using a nucleic acid amplification test (NAAT) that targets alternate gonococcal nucleic acid sequences. Among 59,664 specimens, 280 (0.47%) had positive results using AC2; 265 of these specimens were tested using the confirmatory NAAT, of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 9  شماره 

صفحات  -

تاریخ انتشار 2007