Some aspects of the analysis and the interpretation of electrical measurements of submerged arc-resistance furnace
نویسندگان
چکیده
The article describes measurement of currents and voltages in submerged arc-resistance electric furnace which were done to identify arc parameters. Waveforms of registered currents and voltages have been shown. Characteristics of arc developed in original C# software have been presented. Streszczenie. Artykuł opisuje pomiary prądów i napięć w obwodzie pieca elektrycznego łukowo-oporowego z łukiem krytym, które zostały wykonane w celu identyfikacji parametrów łuku. Zaprezentowano przebiegi zarejestrowanych prądów i napięć. Przedstawiona charakterystyka łuku została wyznaczona za pomocą własnego programu napisanego w języku C#. (Pewne aspekty analizy i interpretacji pomiarów wielkości elektrycznych pieca łukowo-oporowego).
منابع مشابه
The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملThe New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کاملEffect of Heat Input of Submerged Arc Welding Process on the Corrosion Behavior of API X42 Gas Pipeline Steel Weld Joint
The effect of heat input of submerged arc welding process on the corrosion bahavior of weld metal of API X42 gas pipeline steel weld joint was investigated. For this purpose, 6 annealed sheets of 15mm thickness were prepared from the X42 microalloyed steel. Submerged arc welding process with varying heat input of 37.8, 18.9 and 12.6 kJ/mm was used for joint welding. Then potentiodynamic polariz...
متن کاملAnalysis of Transport Phenomena in Submerged Arc Furnace for Ferrochrome Production
Ferrochrome is the major chromium source for stainless steel production, and submerged-arc furnaces (SAF) are most commonly utilised to smelt chromite ores into ferrochrome by using suitable carbonaceous reductants such as coke. Because of the complexity of feed structure and electrical-thermal-chemical interactions, there exist large gradients and wide distributions of temperature, mineralogy ...
متن کامل