Perioperative concentrations of catecholamines in the cerebrospinal fluid and plasma during spinal anesthesia.

نویسندگان

  • M J Oehmke
  • T Podranski
  • M Mann
  • N Frickey
  • D F M Kuhn
  • G Hempelmann
چکیده

BACKGROUND Catecholamine release is a physiological response to stress. The extent to which perioperative stress provokes the central release of catecholamines, which modulate pain perception in the spinal cord, still remains unknown. The perioperative course of catecholamine concentrations in the cerebrospinal fluid (CSF) and plasma was examined. METHODS A prospective study was performed in 25 patients (ASA III, 60-84 years) undergoing elective hip joint replacement in spinal catheter anesthesia. The concentrations of dopamine, epinephrine and norepinephrine in the CSF and plasma were measured before anesthesia, immediately after surgery, and 6 and 24 h post-operatively. RESULTS In most patients, dopamine and epinephrine were not detectable in CSF. CSF-norepinephrine concentrations decreased from median [interquartile-range] 159 [124;216] pre-anesthesia to 116 [79;152] pmol/l immediately post-operatively and were slightly elevated 24 h post-operatively (180 [134;302] pmol/l) (P=0.05). Dopamine plasma concentrations were not detectable or were barely above the detection threshold. Plasma epinephrine increased from 61 [28;77] pmol/l pre-anesthesia to 112 [69;138] pmol/l 6 h post-operatively and returned to baseline 24 h post-operatively (P=0.001). Plasma norepinephrine concentrations increased intra-operatively from 298 [249;422] to 556 [423;649] pmol/l and remained elevated 24 h after surgery (P=0.009). There was no association between changes in CSF or plasma norepinephrine or epinephrine concentrations and changes in heart rate (HR) or mean arterial pressure (MAP). CONCLUSION During spinal anesthesia for elective hip joint replacement, norepinephrine concentrations were greater in plasma than in CSF. CSF dopamine and epinephrine concentrations were essentially undetectable. The changes in CSF-norepinephrine concentrations and the changes of plasma norepinephrine concentrations showed no association with each other; nor were there correlations between clinical stress parameters (HR, MAP) or visual analog scale pain, and the changes in CSF norepinephrine concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebrospinal fluid distribution of ibuprofen after intravenous administration in children.

BACKGROUND Ibuprofen is the most commonly used nonsteroidal, antipyretic, antiinflammatory analgesic in children. Nonsteroidal, antipyretic, antiinflammatory analgesics act in both the peripheral tissues and the central nervous system. The central nervous system penetration of ibuprofen has been described in adults but not in children. OBJECTIVES Our goals were to investigate the cerebrospina...

متن کامل

OBSTETRICS Effects of pre-eclampsia on maternal plasma, cerebrospinal fluid, and umbilical cord urotensin II concentrations: a pilot studyy

Background. Urotensin II (UII) is the most potent endogenous vasoconstrictor identified to date. Pre-eclampsia is associated with arteriolar vasospasm but the precise underlying mechanism is uncertain and we hypothesized that UII concentrations might also be elevated. In this study we measured UII concentrations in maternal plasma and cerebrospinal fluid (CSF), and umbilical vein plasma from pr...

متن کامل

بررسی فاصله پوست تا فضای ساب آراکنویید در بی حسی اسپاینال

Background and purpose: Spinal anesthesia is one of the most common techniques in general surgery. We studied the distance from skin to spine to determine whether there is any relationship between patients age, body mass index (BMÏ), weight and the distance from the skin to the spine. The measurment of the distance from skin to the spine is not as well preformed as the distance from skin to t...

متن کامل

Morphine in Plasma and Cerebrospinal Fluid of Patients Addicted to Opiates Undergoing Surgery: High-performance Liquid Chromatography Method

Background: The prevalence of opium addiction among Iranians is considerable. Since endogenous opioid systems may be altered as a consequence of addiction, it is very important to determine the plasma and cerebrospinal fluid (CSF) levels of morphine in Iranian patients addicted to opiates who will undergo surgery.Methods: We obtained CSF and plasma samples from 50 volunteers with an established...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta anaesthesiologica Scandinavica

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2008