Inter-Turn Fault Detection in Power transformer Using Wavelets

نویسنده

  • K. Ramesh
چکیده

Detection and removal of incipient faults in power transformer winding is essential because minor faults may develop and lead to major faults and finally irretrievable damages occur. This research article presenta a new, simple and incipient fault detection technique, which is based on symmetrical component approach. Using this protection technique, it is possible to detect minor turn-to-turn faults in power transformers. This protection technique is being studied via an extensive simulation study using MATLAB/SIMULINK software in three phase power system. The new protection principle is based on the theory of symmetrical components, or more exactly, on the negative sequence currents. To have accurate feature extraction and to improve the sensitivity of proposed technique, wavelet transform (WT) has been employed. In this paper a multi winding transformer of 100 MVA, 138/13.8 KV, Y-Y is simulated using MATLAB software. Different percentages of inter turns of power transformer are short circuited and it is observed that the changes in transformer terminals current is very small. To observe significant changes, negative sequence currents are extracted using symmetrical component approach. The phase angle shift on both sides of the transformer during incipient faults is found to be significant. However, to improve the sensitivity of the proposed technique, wavelet has been employed. Using the wavelet “db3” at level4 the phase angle variations of negative sequence currents during fault incidence period are analyzed. The absolute peak values of detailed1 coefficients on primary and secondary sides are calculated. The ratio of absolute peaks on faulted side to that of non-faulted side is used for feature extraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Modelling and Simulation of a Transformer With Inter-turn Fault Including Saturation Effect and Variable Fault Parameters

This investigation deals with a mathematical model for a distribution transformer including saturation effect. To this end, the equations related to a three phase transformer are specified and the effect of an inter-turn fault is included. Naturally by applying an inter-turn fault the inductance and resistance matrix will change. Thus, unknown quantities of inductances and resistances for compl...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model b...

متن کامل

Discrimination between Inrush and Fault in Transformer: ANN Approach

Transformer protection is critical issue in power system as the issue lies in the accurate and rapid discrimination of magnetizing inrush current from internal fault current. Artificial neural network has been proposed and has demonstrated the capability of solving the transformer monitoring and fault detection problem using an inexpensive, reliable, and noninvasive procedure. This paper gives ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014