Measurement of functional residual capacity during high-frequency oscillatory ventilation (HFOV) by argon washout method without interruption of HFOV.

نویسندگان

  • H Imanaka
  • J Takezawa
  • M Nishimura
  • M Nishijima
  • N Taenaka
  • I Yoshiya
چکیده

A modified indicator gas washout method was developed to measure functional residual capacity (FRC) during high-frequency oscillatory ventilation (HFOV) without interruption of HFOV. A hot-wire flowmeter and medical gas analyzer measured the flow rate and argon concentration, respectively, at the expiratory end of the respiratory circuit. Upstream of the hot-wire flowmeter, two heat-and-moisture exchangers for resistance and a rubber balloon for capacitance were placed to convert the oscillating expiratory flow to an almost continuous flow. This made it possible to measure FRC during HFOV without interrupting HFOV. To measure the volume of the entire respiratory circuit, a 10 percent argon in 90 percent oxygen gas mixture was initially used as a bias flow, and after equilibration, the test gas was switched to 100 percent oxygen. By electrical integration of the product of the expiratory flow rate and argon concentration, the total amount of argon equilibrated in the entire respiratory circuit was calculated. The volume of the circuit was calculated by dividing the total amount of argon by the initial argon concentration. Functional residual capacity plus the volume of the respiratory circuit was similarly calculated and the difference was estimated as FRC. The accuracy and reproducibility of our method were evaluated by using a one-compartment lung model. There was a high correlation between the volume setting of the model lung and the estimated FRC. This method can be used to estimate FRC in a one-compartment lung model during HFOV, and it is potentially useful in clinical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous noninvasive monitoring of lung recruitment during high-frequency oscillatory ventilation by electrical impedance measurement: an animal study.

BACKGROUND Ventilatory pressures should target the range between the upper and lower inflection point of the pressure volume curve in order to avoid atelecto- and volutrauma. During high-frequency oscillatory ventilation (HFOV), this range is difficult to determine. Quadrant impedance measurement (QIM) has recently been shown to allow accurate and precise measurement of lung volume changes duri...

متن کامل

Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome

BACKGROUND To compare the effect of a sustained inflation followed by an incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation on oxygenation and hemodynamics in a large porcine model of early acute respiratory distress syndrome. METHODS Severe lung injury (Ali) was induced in 18 healthy pigs (55.3 +/- 3.9 kg, mean +/- SD) by repeated saline lun...

متن کامل

High-frequency oscillatory ventilation after cardiac surgery: a treatment for all ages

a recent issue of Critical Care, Bojan and colleagues [1] reported their experience with early initiation of high-frequency oscillatory ventilation (HFOV) in pediatric cardiac surgery that demonstrated shorter mechanical ventilation times and intensive care stays. Acute lung injury is common in adult patients undergoing surgery, yet there is scant reporting of the intraoperative utility of HFOV...

متن کامل

Combined oscillatory and mandatory ventilation in newborn infants

When intermittent mandatory ventilation (IMV) and/or high frequency oscillatory ventilation (HFOV) fails to improve respiratory failure, the imposition of HFOV during IMV has been shown to facilitate alveolar recruitment and improve oxygenation. This mode of ventilation has been referred to as combined oscillatory and mandatory ventilation (COMV) or high frequency oscillation-intermittent venti...

متن کامل

High-frequency oscillatory ventilation is not superior to conventional mechanical ventilation in surfactant-treated rabbits with lung injury.

The aim of this study was to compare high-frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CMV) with and without surfactant in the treatment of surfactant-deficient rabbits. A previously described saline lung lavage model of lung injury in adult rabbits was used. The efficacy of each therapy was assessed by evaluating gas exchange, lung deflation stability and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 1990