DNA separation and fluorescent detection in an optofluidic chip with sub-base-pair resolution

نویسندگان

  • Markus Pollnau
  • Manfred Hammer
  • Chaitanya Dongre
  • Hugo J. W. M. Hoekstra
چکیده

DNA sequencing in a lab-on-a-chip aims at providing cheap, high-speed analysis of low reagent volumes to, e.g., identify genomic deletions or insertions associated with genetic illnesses. Detecting single base-pair insertions/deletions from DNA fragments in the diagnostically relevant range of 1501000 base-pairs requires a sizing accuracy of S < 10. Here we demonstrate S = 410. A microfluidic chip was post-processed by femtosecond-laser writing of an optical waveguide. 12 blue-labeled and 23 red-labeled DNA fragments were separated in size by capillary electrophoresis, each set excited by either of two lasers power-modulated at different frequencies, their fluorescence detected by a photomultiplier, and blue/red signals distinguished by Fourier analysis. Different calibration strategies were tested: a) use either set of DNA molecules as reference to calibrate the set-up and identify the base-pair sizes of the other set in the same flow experiment, thereby eliminating variations in temperature, wall-coating and sieving-gel conditions, and actuation voltages; b) use the same molecular set as reference and sample with the same fluorescence label, flown in consecutive experiments; c) perform cross-experiments based on different molecular sets with different labels, flown in consecutive experiments. From the results we conclude: Applying quadratic instead of linear fit functions improves the calibration accuracy. Blue-labeled molecules are separated with higher accuracy. The influence of dye label is higher than fluctuations between two experiments. Choosing a single, suitable dye label combined with reference calibration and sample investigation in consecutive experiments results in S = 410, enabling detection of single base-pair insertion/deletion in a lab-on-a-chip.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined microfluidic-optical DNA analysis with single-base-pair sizing capability.

DNA sequencing by microchip capillary electrophoresis (CE) enables cheap, high-speed analysis of low reagent volumes. One of its potential applications is the identification of genomic deletions or insertions associated with genetic illnesses. Detecting single base-pair insertions or deletions from DNA fragments in the diagnostically relevant size range of 150-1000 base-pairs requires a varianc...

متن کامل

Modulation-frequency encoded multi-color fluorescent DNA analysis in an optofluidic chip.

We introduce a principle of parallel optical processing to an optofluidic lab-on-a-chip. During electrophoretic separation, the ultra-low limit of detection achieved with our set-up allows us to record fluorescence from covalently end-labeled DNA molecules. Different sets of exclusively color-labeled DNA fragments-otherwise rendered indistinguishable by spatio-temporal coincidence-are traced ba...

متن کامل

Multi-color DNA Analysis in an Optofluidic Chip

Sorting and sizing of DNA molecules by capillary electrophoresis (CE) within the human genome project have enabled the genetic mapping of various illnesses. By the use of miniaturized lab-on-achip devices, on-chip-integrated DNA sequencing and genetic diagnostics have become feasible. The inherent advantages of microfluidic CE separation of differently sized DNA molecules, high-speed operation ...

متن کامل

Dual-point dual-wavelength fluorescence monitoring of DNA separation in a lab on a chip

We present a simple approach in electrophoretic DNA separation and fluorescent monitoring that allows to identify the insertion or deletion of base-pairs in DNA probe molecules from genetic samples, and to perform intrinsic calibration/referencing for highly accurate DNA analysis. The principle is based on dual-point, dual-wavelength laser-induced fluorescence excitation using one or two excita...

متن کامل

Multi-color fluorescent DNA analysis in an optofluidic chip

In a commercial microfluidic chip (LioniX BV), a plug of DNA molecules with a volume of ~605 pl was injected and the DNA molecules were CE-separated with a high relative sizing accuracy of > 99% [1]. Through an optical waveguide inscribed by femtosecond-laser writing [2] a laser was launched perpendicularly into the microfluidic channel. A photomultiplier collected the fluorescence signals from...

متن کامل