Comparison between the long-axis/in-plane and short-axis/out-of-plane approaches for ultrasound-guided vascular catheterization: an updated meta-analysis and trial sequential analysis

نویسندگان

  • Chao Liu
  • Zhi Mao
  • Hongjun Kang
  • Xin Hu
  • Shengmao Jiang
  • Pan Hu
  • Jie Hu
  • Feihu Zhou
چکیده

Background A long-axis in-plane (LA-IP) approach and a short-axis out-of-plane (SA-OOP) approach are the two main approaches used in ultrasound (US)-guided vascular catheterization. However, the efficacy and safety of these approaches remain controversial. Therefore, we performed this meta-analysis to compare the two techniques in vascular catheterization. Materials and methods Relevant studies were searched in PubMed, Embase, and the Cochrane Library databases from database inception until August 2017. Randomized controlled trials comparing a long-axis approach with a short-axis approach for US-guided vascular cannulation were selected. The RevMan software was used to analyze the results, and trial sequential analysis (TSA) was further applied to determine whether the currently available evidence was sufficient and conclusive. Results Eleven studies met the inclusion criteria. Overall, 1,210 patients were included. The total success rate was similar between the SA-OOP and LA-IP approaches for US-guided vascular catheterization (risk ratio [RR], 1.01; 95% CI, 0.99-1.04; P=0.35; I2=48%). In the radial artery (RA; RR, 1.00; 95% CI, 0.96-1.05; P=0.88; I2=49%) and internal jugular vein (IJV; RR, 1.00; 95% CI, 0.98-1.02; P=0.99; I2=0%) subgroups, the total success rate was also similar and was confirmed by the TSA. For populations with subclavian vein (SCV) and axillary vein catheterization, the SA-OOP approach showed a benefit for first-attempt success rate. No significant differences in first-attempt success rate, cannulation times, or complications were found between the two approaches. Conclusion Despite a similar total success rate between the SA-OOP approach and the LA-IP approach when used for RA and IJV catheterization (as confirmed by TSA), further robust well-designed trials are warranted to evaluate other outcomes. There is insufficient evidence to definitively state that the SA-OOP approach was superior to the LA-IP approach when used for SCV and axillary vein catheterization. High-quality trials are needed to confirm or refute this finding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach.

OBJECTIVES Ultrasound guidance for central venous catheterization improves success rates and decreases complications when compared to the landmark technique. Prior research has demonstrated that arterial and/or posterior vein wall puncture still occurs despite real-time ultrasound guidance. The inability to maintain visualization of the needle tip may contribute to these complications. This stu...

متن کامل

A randomized comparison of long-and short-axis imaging for in-plane ultrasound-guided femoral perineural catheter insertion.

OBJECTIVES Continuous femoral nerve blocks provide effective analgesia after knee arthroplasty, and infusion effects depend on reliable catheter location. Ultrasound-guided perineural catheter insertion using a short-axis in-plane technique has been validated, but the optimal catheter location relative to target nerve and placement orientation remain unknown. We hypothesized that a long-axis in...

متن کامل

Efficacy of Adding Magnesium Sulfate to Ropivacaine in Ultrasound-guided Transversus Abdominis Plane Block on Analgesia After Open Appendectomy

Introduction: Proper management of postoperative pain relieves the patient’s discomfort, reduces the length of hospitalization, reduces hospital costs, and increases patient satisfaction. This study was aimed to determine the efficacy of adding magnesium sulfate to ropivacaine 0.25% in transverse abdominis plane (TAP) block under ultrasound guidance on analgesia after open appendectomy. Method...

متن کامل

The oblique view: an alternative approach for ultrasound-guided central line placement.

BACKGROUND Numerous studies have shown significant benefits of using real-time ultrasonography for central line intravenous access. Traditionally, the ultrasound probe is placed along the short axis of the vein to visualize and direct needle placement. This view has some limitations, particularly being able to visualize the needle tip. Some practitioners place the ultrasound probe in the long a...

متن کامل

Real-time ultrasound detection of correct intravenous placement of central venous catheters after ultrasound cannulation.

Ultrasound-guided technique for central venous catheterization has been a widely developed procedure during the last decade. Nowadays, it is a common technique in the anaesthesiologist’s clinical practice. During the last six years, we usually have carried out central venous catheterization using the ultrasound-guided technique in our hospital. Moreover, we use to check correct intravenous plac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2018