Patient state index vs bispectral index as measures of the electroencephalographic effects of propofol.
نویسندگان
چکیده
BACKGROUND The patient state index (PSI) and the bispectral index (BIS) quantify anaesthetic depth based on the EEG using different algorithms. We compared both indices with regard to the prediction of the depth of propofol anaesthesia. METHODS In 17 patients, propofol was infused until burst suppression occurred and stopped thereafter until BIS recovered to values above 60. This was repeated; afterwards, patients were intubated, for subsequent surgery. Without surgical stimulus, PSI and BIS were measured simultaneously and compared with the estimated effect-site concentrations of propofol. These were derived from simultaneous pharmacokinetic and -dynamic modelling in an individual two-stage and a population-based NONMEM approach. RESULTS A close sigmoid relationship was observed between the propofol effect-site concentration and both PSI [coefficient of determination rho(2)=0.91 (sd 0.05)] and BIS [rho(2)=0.92 (0.03)], which was significantly steeper for PSI [gamma=2.2 (0.6)] than for BIS [gamma=1.8 (0.4)], and reached significantly lower values for PSI [E(max)=0.3 (1.1)] than for BIS [E(max)=5.3 (6.7)] at maximal propofol concentrations. A significantly smaller k(e0) was obtained for PSI [0.09 (0.03) min(-1)] compared with BIS [0.10 (0.02) min(-1)]. PSI and BIS correlated significantly with each other (rho(2)=0.866) and predicted propofol effect-site concentration with a comparable probability [P(K)=0.87 (0.05) and 0.86 (0.05), respectively]. NONMEM revealed E(0)=89.3 and 92.3, E(max)=1.9 and 8.6, C(e50)=1.38 and 1.92 microg ml(-1), gamma=1.6 and 1.48, and k(e0)=0.103 and 0.131 min(-1) as typical values for PSI and BIS, respectively. CONCLUSIONS The PSI and the BIS monitors performed equally well in predicting depth of propofol anaesthesia. However, PSI was lower than BIS by approximately 10-15 points at high propofol concentrations.
منابع مشابه
NEUROSCIENCES AND NEUROANAESTHESIA Patient state index vs bispectral index as measures of the electroencephalographic effects of propofol
M. Soehle 1*, M. Kuech 1, M. Grube 1, S. Wirz 1,2, S. Kreuer 3, A. Hoeft 1, J. Bruhn 1,4 and R. K. Ellerkmann 1 1 Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, Sigmund-Freud-Str. 25, D-53105 Bonn, Germany 2 Department of Anaesthesiology and Intensive Care Medicine, CURA Hospital, Bad Honnef, Germany 3 Department of Anaesthesiology and Intensive Care Medicine, Un...
متن کاملARX-derived auditory evoked potential index and bispectral index during the induction of anesthesia with propofol and remifentanil.
UNLABELLED A new commercial auditory evoked potential (AEP) monitor (A-line AEP monitor) was developed to calculate an index (ARX AEP index; AAI) by automatically using the amplitudes and latencies of the AEP. We investigated 30 patients before spine surgery. AAI; bispectral index (BIS); relative (%) delta, theta, alpha, and beta; spectral edge frequency; median frequency; mean arterial blood p...
متن کاملCorrelation between Bispectral Index and Predicted Effect-site Concentration of Propofol in Different Levels of Target-Controlled, Propofol Induced Sedation in Healthy Volunteers
Introduction: Bispectral Index is an objective tool to assess electroencephalographic activity and measure the effect of certain sedatives and hypnotics on the brain. In addition, there are certain subjective tools such as the observer's assessment of alertness and sedation which are used. The correlation between BIS and the concentration of propofol in the brain, and the relationship between t...
متن کاملBispectral index-guided sedation with dexmedetomidine in intensive care: a prospective, randomized, double blind, placebo-controlled phase II study.
OBJECTIVE To compare dexmedetomidine vs. placebo with respect to the amount of additional propofol and morphine used for bispectral index-guided sedation and analgesia in mechanically ventilated, intensive care patients after surgery. DESIGN Prospective, randomized, double blind, placebo-controlled, phase II clinical trial. SETTING General surgical and cardiac surgical intensive care units....
متن کاملElectromyographic activity falsely elevates the bispectral index.
THE bispectral index (BIS, Aspect Medical Systems, Framingham, MA) is a complex electroencephalographic (EEG) parameter that integrates several disparate descriptors of the EEG into a single variable and correlates behavioral assessments of sedation and hypnosis. We report two cases in which the bispectral index failed to measure depth of anesthesia but instead was a measure of electromyographi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 105 2 شماره
صفحات -
تاریخ انتشار 2010