Reference ranges for the linear dimensions of the intracranial ventricles in preterm neonates.

نویسندگان

  • M W Davies
  • M Swaminathan
  • S L Chuang
  • F R Betheras
چکیده

AIMS To establish normal ranges, in preterm infants < 33 weeks' gestation, for measurements of the lateral, third, and fourth ventricles and to assess intra-observer and inter-observer reliability. To assess the effect of head position during scanning on lateral ventricle size. To determine whether sex influences ventricle size. METHODS A prospective study involving infants < 33 weeks' gestational age (GA) at birth. Cranial ultrasound scans were done during the first 3 days of life. Linear dimensions of the anterior horn width and thalamo-occipital distance of the lateral ventricles, the width of the third ventricle, and the width and length of the fourth ventricle were measured. Measurements were plotted against GA and reference ranges produced. All measurements were tested for intra-observer and inter-observer reliability. Head position and sex differences were studied. RESULTS 120 infants with known GA (23(+1) to 32(+6) weeks) had their intracranial ventricles measured. Reference ranges obtained were-anterior horn width: 0-2.9 mm; thalamo-occipital distance: 8.7-24.7 mm; third ventricle width: 0-2.6 mm; fourth ventricle width: 3.3-7.4 mm; fourth ventricle length: 2.6-6.9 mm. Dependent and non-dependent lateral ventricles did not differ significantly in size. There was no clinically significant difference in ventricular size between sexes. CONCLUSIONS Reference ranges for the measurement of the intracranial ventricles in preterm infants from 23 to 33 weeks' GA are provided and can be used in the diagnosis and assessment of ventricular enlargement in preterm infants. All measurements have good intra-observer and inter-observer reliability. Head position at the time of scanning does not influence the asymmetry of the lateral ventricular measurements. The infant's sex does not influence ventricular size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound Measurement of Kidney Dimensions in Premature Neonates

Background Ultrasonography is a non-invasive and accurate diagnostic method to evaluate urinary system and its anomalies in the neonates. Kidney sonographic measurement can be used as an alternative method to estimate gestational age. The aim of this study was to measure kidney size in preterm neonates and to provide a guide reference for gestational age. <...

متن کامل

REVIEW ARTICLE: Ultrasound measurements of the lateral ventricles in neonates: why, how and when? A systematic review

DOI:10.1111/j.1651-2227.2010.01830.x ABSTRACT Germinal matrix-intraventricular haemorrhage and subsequent post-haemorrhagic ventricular dilatation (PHVD) are frequently encountered complications in preterm neonates. As progressive dilatation of the lateral ventricles may be associated with elevated intracranial pressure, ultrasound measurements of ventricular size play a major role in the evalu...

متن کامل

Survival of Extremely Preterm Neonates in a Resource-limited Setting

Background: Preterm birth is a major contributor to neonatal and under-five mortality, and births at lower gestational ages (GA) contribute more to these statistics. Most developed countries have succeeded in improving survival at extremes of GA, while most developing countries like Nigeria still lag behind. The objective of this retrospective study was to document the...

متن کامل

Presepsin (Soluble CD14 Subtype): Reference Ranges of a New Sepsis Marker in Term and Preterm Neonates

OBJECTIVE Presepsin (soluble CD14 subtype) has been shown to be beneficial as a sepsis marker in adults. Nevertheless, very few data are available in neonates. The aim of the present study was to determine reference ranges of presepsin in term and preterm neonates. METHODS Healthy term neonates and preterm neonates without clinical signs of infection admitted to the Neonatal Unit were consecu...

متن کامل

Reference ranges for cardiac dimensions and blood flow velocity in preterm infants.

AIM To establish reference ranges for cardiac dimensions and Doppler measurements in preterm infants. METHODS 79 infants of less than 34 weeks' gestation were examined by echocardiography on days 0, 7, and 28 after birth, to produce a set of reference ranges and to examine changes in these indices over the first month of life. The following dimensions were measured: interventricular septum, l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 2000