Peri-implant and systemic effects of high-/low-affinity bisphosphonate-hydroxyapatite composite coatings in a rabbit model with peri-implant high bone turnover
نویسندگان
چکیده
BACKGROUND Hydroxyapatite (HA) coatings composed with bisphosphonates (BPs) which have high mineral-binding affinities have been confirmed to successfully enhance implant stability. However, few previous studies focused on HA coatings composed with low-affinity BPs or on systemic effects of locally released BPs. METHODS In this long-term study, we developed two kinds of BP-HA composite coatings using either high-affinity BP (alendronate, ALN) or low-affinity BP (risedronate, RIS). Thirty-six rabbits were divided into three groups according to different coating applications (group I: HA, group II: ALN-HA, and group III: RIS-HA). Implants were inserted into the proximal region of the medullary cavity of the left tibiay. At insertion, 2 × 10(8) wear particles were injected around implants to induce a peri-implant high bone turnover environment. Both local (left tibias) and systemic (right tibias and lumbar vertebrae) inhibitory effect on bone resorption were compared, including bone-implant integration, bone architecture, bone mineral density (BMD), implant stability, and serum levels of bone turnover markers. RESULTS The results indicated that ALN-HA composite coating, which could induce higher bone-implant contact (BIC) ratio, bone mass augmentation, BMD, and implant stability in the peri-implant region, was more potent on peri-implant bone, while RIS-HA composite coating, which had significant systemic effect, was more potent on non-peri-implant bone, especially lumbar vertebrae. CONCLUSIONS It is instructive and meaningful to further clinical studies that we could choose different BP-HA composite coatings according to the patient's condition.
منابع مشابه
تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملDetermining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021
Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...
متن کاملAdipose- Derived Stem Cells as a Tool for Dental Implant Osseointegration: an Experimental Study in the Dog
The biological interaction between the jaw bones and dental implant is fundamental for the long-term success of dental implant placement. Nevertheless, the insufficient bone volume remains a major clinical problem, especially in case of immediate dental implant. Using a canine model, the present study proves the regenerative potential of adipose- derived stem cells (ADSCs) to repair peri-implan...
متن کاملتعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملOrthopedic Implants Used as Drug Delivery Systems: Numerical, in Vitro and in Vivo Studies
Total Hip Replacement (THR) is today a routine procedure executed more than 800’000 times per year worldwide. THR gives generally satisfactory results, although the quality of outcome is inversely proportional to the age of the patient. In parallel, there is a trend to propose cementless THR to patients younger than 60 years. These patients have more demanding physical activity resulting in a s...
متن کامل